A group of dry contact input (Auxiliary In) was available on Energier pro Inverter Charger Combination, of which can be used to remotely
turn off the equipment.
Only Dry Contact.
Please find following chart the default setting:
2.18 Dry contact
Dry Contact Input
A group of dry contact output (Auxiliary Out) was available on Energier pro Inverter Charger Combination. The default setting of this dry
contact output was battery low voltage.It will activate once the voltage was detected dropping to preset level. This dry contact can be used
for load management or other function.
Through Vision Lite or Rapconfig, other functions can be configured for this contact.
Dry Contact Output
LVD setting
10.5 VDC
11.7 VDC
Default
11 VDC
12 VDC
Default
22 VDC
24 VDC
LVD setting
21 VDC
23.4 VDC
LVD setting
42 VDC
46.8 VDC
Default
44 VDC
48 VDC
The maximum contact load is:
230 VAC : 2 A
12 VDC / 24 VDC / 36 VDC : 2 A
Содержание Energier Pro CF2060L
Страница 1: ...User Manual Energier Pro series Inverter Charger Combination TBB Power CO ltd www tbbpower com A3 4...
Страница 2: ...Energier pro User Manual...
Страница 23: ...Energier pro User Manual 16 3 1 2 RCF remote 3 1 3 Vision Lite 3 1 4 AGS 3 1 5 TAI...
Страница 25: ...Energier pro User Manual 18 3 CF4080M CF50100M CF5050S CF6060S CF8080S 3 2 2 RCF remote 3 2 3 Vision Lite...
Страница 26: ...Energier pro User Manual 19 3 2 4 AGS 3 2 5 TAI...
Страница 59: ...Energier pro User Manual...