Quit
Troubleshooting
Insufficient mix in the freezing
cylinder (continued).
Cause: Improper seal of suction line to the
mix inlet fitting.
Remedy: Remove the suction line from the
mix inlet fitting. Place under hot running
water, allow tubing to swell, then cool.
Connect suction line to barbed fitting.
Eventual replacement will be necessary.
Cause: The mix inlet tube is frozen or clogged.
Remedy: Use the long, flexible brush and
sanitizing solution to clear the restriction in the
mix inlet tube. Contact an authorized service
technician to correct the cause of over-
refrigeration in the mix cabinet.
Cause: Defective air/mix pump pressure switch.
Remedy: Contact an authorized service
technician to replace the pressure switch.
Cause: The mix pump ball crank is broken.
Remedy: Contact an authorized service
technician to replace the ball crank.