Quit
Troubleshooting
Product is too soft.
Cause: Worn scraper blades.
Remedy: Replace blades regularly.
Cause: Dirty condensers or air filters on air
cooled units.
Remedy: Clean monthly.
Cause: Inadequate air space around air
cooled units.
Remedy: Allow adequate room for air flow
across condensers. Minimum of 3” (7.6 cm)
clearance on all sides. Do not obstruct air
discharge on top. There should be 12” (30.5
cm) clearance on top of freezer.
Cause: Inadequate water supply on water
cooled units.
Remedy: Check the water supply. Check water
lines for leaks or kinks.
Cause: Draw rate is set too fast.
Remedy: Adjust the draw rate to 5 to 7½ oz. of
product every 10 seconds. Check that the
restrictive bar on the draw handle is assembled
on the bottom.
Cause: Viscosity control is set too warm.
Remedy: Contact an authorized service
technician.