Quit
Troubleshooting
Insufficient mix in the freezing
cylinder.
Cause: Suction line is not fully submerged in
the mix.
Remedy: Arrange the suction line so the
weighted end is fully submerged.
Cause: Worn or defective check bands or o-
rings in air/mix pump assembly.
Remedy: Replace regularly. Never lubricate
check bands.
Cause: Missing, defective, or no lubrication
on the mix inlet fitting o-ring.
Remedy: Replace or evenly lubricate the o-
ring on the mix inlet fitting.
Cause: The mix pump is pumping foam.
Remedy: Incorrect handling of rerun. Remove
all foam.
Cause: Pressure switch diaphragm installed
incorrectly, or missing.
Remedy: Diaphragm must be correctly installed
in the pressure switch cap or the housing.
Cause: The pump motor is not activated.
Remedy: Place the power switch in the OFF
position. Push the reset button on the pump
drive motor. Return the power switch to the ON
position. Press the AUTO key.