TO THE INSTALLER
1-3
Model C706
To the Installer
1
IMPORTANT!
This machine is provided with an
equipotential grounding lug that is to be properly
attached to the rear of the frame by the authorized
installer. The installation location is marked by the
equipotential bonding symbol (5021 of IEC 60417-1) on
both the removable panel and the machine’s frame.
Stationary machines which are not equipped with a
power cord and a plug or other device to disconnect the
machine from the power source must have an all-pole
disconnecting device with a contact gap of at least
0.125 in. (3 mm) installed in the external installation.
Machines that are permanently connected to fixed wiring
and for which leakage currents may exceed 10 mA,
particularly when disconnected or not used for long
periods, or during initial installation, shall have protective
devices to protect against the leakage of current, such as
a GFI, installed by the authorized personnel to the local
codes.
Supply cords used with this machine shall be oil-
resistant, sheathed flexible cable not lighter than ordinary
polychloroprene or other equivalent synthetic elastomer-
sheathed cord (code designation 60245 IEC 57) installed
with the proper cord anchorage to relieve conductors
from strain, including twisting, at the terminals and
protect the insulation of the conductors from abrasion.
Beater Rotation
NOTICE!
Beater rotation must be clockwise as
viewed looking into the freezing cylinder.
To correct the rotation on a three-phase machine,
interchange any two incoming power supply lines at the
freezer main terminal block only. To correct rotation on a
single-phase machine, exchange leads inside the beater
motor. (Follow the diagram printed on the motor.)
Electrical connections are made directly to the terminal
block provided in the main control box located behind the
service panel.
It is recommended that beater rotation adjustment be
performed by an authorized Taylor service technician.
Refrigerant
CAUTION!
This machine contains fluorinated
greenhouse gases (F-Gas) to provide refrigeration using
a hermetically sealed circuit or within foam insulation.
This machine’s type of gas, quantity, Global Warming
Potential (GWP) and CO
2
tonnes equivalent information
is recorded on the machine’s data label. The refrigerant
used is generally considered nontoxic and
nonflammable. However any gas under pressure is
potentially hazardous and must be handled with caution.
NEVER
fill any refrigerant cylinder completely with liquid.
Filling the cylinder to approximately 80% will allow for
normal expansion.
CAUTION!
Use only approved refrigerant
listed on the machine's data label or authorized through a
manufacturer's technical bulletin. The use of any other
refrigerant may expose users and operators to
unexpected safety hazards.
WARNING!
Refrigerant liquid sprayed onto the
skin may cause serious damage to tissue. Keep eyes
and skin protected. If refrigerant burns should occur,
flush the area immediately with cold water. If burns are
severe, apply ice packs and contact a physician
immediately.
IMPORTANT!
Refrigerants and their
associated lubricants may be extremely moisture
absorbent. When opening a refrigeration system, the
maximum time the system is open must not exceed 15
minutes. Cap all open tubing to prevent humid air or
water from being absorbed by the oil.
Содержание C706
Страница 8: ...1 4 TO THE INSTALLER Model C706 To the Installer 1 Notes ...
Страница 14: ...3 4 SAFETY Model C706 Safety 3 Notes ...
Страница 36: ...6 14 OPERATING PROCEDURES Model C706 Operating Procedures 6 Notes ...
Страница 42: ...8 4 TROUBLESHOOTING GUIDE Model C706 Troubleshooting Guide 8 Notes ...
Страница 44: ...9 2 PARTS REPLACEMENT SCHEDULE Model C706 Parts Replacement Schedule 9 Notes ...
Страница 48: ...10 4 LIMITED WARRANTY ON EQUIPMENT Model C706 Limited Warranty on Equipment 10 Notes ...
Страница 52: ...11 4 LIMITED WARRANTY ON PARTS Model C706 Limited Warranty on Parts 11 Notes ...