5-2
USER INTERFACE
Model C706
User Interface
5
Symbol Definitions
To better communicate in the international arena,
symbols have replaced words on many of our operator
switches, function, and fault indicators. Your Taylor
machine is designed with these International symbols.
The following chart identifies the symbol definitions:
= OFF
=
ON
= MIX LOW
= MIX OUT
= MIX REF
= STANDBY
= WASH
= AUTO
= PUMP
Power Switch
When placed in the ON position, the power switch allows
Softech™ control panel operation.
Indicator Lights
When the MIX LOW indicator light flashes, the mix tank
has a low supply of mix and should be refilled as soon as
possible. When the MIX OUT indicator light begins to
flash, the mix tank has been almost completely
exhausted and has an insufficient supply of mix to
operate the freezer. At this time, the Standby and Auto
modes are locked out and the freezer shuts down. To
initiate the refrigeration system, add mix to the tank and
press the AUTO key. The freezer will automatically begin
operation.
MIX REF Key
When the MIX REF key is pressed, the indicator light
comes on and the mix hopper refrigeration system is
operating. The MIX REF function cannot be canceled
unless the Auto or Standby modes are canceled first.
STANDBY Key
The separate hopper refrigeration (SHR) system and the
cylinder temperature retention (CTR) system are
standard features. The SHR system uses a separate
small refrigeration system to maintain the mix in the
hopper below 40°F (4.4°C) to ensure bacteria control.
The CTR system works with the SHR system to maintain
a good quality product. During long no sale periods, it is
necessary to warm the product in the freezing cylinder to
approximately 35°F to 40°F (1.7°C to 4.4°C) to prevent
overbeating and product breakdown.
To activate the SHR system and CTR system, press the
STANDBY key. Remove the air orifice and place the feed
tube (end without the hole) into the mix inlet hole.
When the STANDBY key is pressed, the indicator light
comes on, indicating the CTR system has been
activated. In the Standby mode, the Wash and Auto
functions are automatically canceled. The Mix Ref
function is automatically locked in to maintain the mix in
the hopper.
To resume normal operation, press the AUTO key. When
the machine cycles off, the product in the freezing
cylinder is at serving viscosity. At this time, place the feed
tube
(end with the hole) into the mix inlet hole and install
the air orifice.
WASH Key
When the WASH key is pressed, the indicator light
comes on showing that the beater motor is operating.
The Standby or Auto modes must be canceled first to
activate the Wash mode.
Содержание C706
Страница 8: ...1 4 TO THE INSTALLER Model C706 To the Installer 1 Notes ...
Страница 14: ...3 4 SAFETY Model C706 Safety 3 Notes ...
Страница 36: ...6 14 OPERATING PROCEDURES Model C706 Operating Procedures 6 Notes ...
Страница 42: ...8 4 TROUBLESHOOTING GUIDE Model C706 Troubleshooting Guide 8 Notes ...
Страница 44: ...9 2 PARTS REPLACEMENT SCHEDULE Model C706 Parts Replacement Schedule 9 Notes ...
Страница 48: ...10 4 LIMITED WARRANTY ON EQUIPMENT Model C706 Limited Warranty on Equipment 10 Notes ...
Страница 52: ...11 4 LIMITED WARRANTY ON PARTS Model C706 Limited Warranty on Parts 11 Notes ...