8-2
TROUBLESHOOTING GUIDE
Model C706
Troubleshooting Guide
8
8. Excessive mix leakage
into the rear drip pan.
a. Missing or worn seal on the
driveshaft.
a. Install or replace regularly.
b. The rear shell bearing is worn.
b. Call Taylor service technician to
replace rear shell bearing.
- - -
9. Excessive mix leakage
from door spout.
a. Missing or worn draw valve
O-rings.
a. Install or replace regularly.
b. Inadequate lubrication of draw
valve O-rings.
b. Lubricate properly.
c. Wrong type of lubricant is being
used (example: petroleum-based
lubricant).
c. Use the proper lubricant (example:
Taylor Lube).
10.No freezer operation
after pressing the AUTO
key.
a. Machine is unplugged.
a. Plug into wall receptacle.
- - -
b. The circuit breaker is off or the fuse
is blown.
b. Turn the breaker on or replace the
fuse.
- - -
c. The beater motor is out on reset.
c. Reset the freezer.
11.Product is not feeding
into the freezing
cylinder.
a. Inadequate level of mix in the mix
hopper.
a. Fill the mix hopper with mix.
b. The mix inlet hole is frozen up.
b. The mix hopper temperature needs
adjustment. Call a Taylor service
technician.
- - -
12.The air/mix pump will
not operate when the
PUMP key is pressed.
a. The circuit breaker is off.
a. Check the breaker.
- - -
b. The power cord is unplugged.
b. Plug in the power cord.
- - -
c. The freezer is out on reset.
c. Reset the freezer.
d. The pump motor is out on reset.
d. Press the PUMP key to cancel pump
operation. Press the Reset button on
the side of the pump motor reducer.
Press the PUMP key to continue
pump operation.
- - -
13.The air/mix pump will
not operate when the
draw valve is opened
and the machine is in
the Auto mode.
a. The pump motor is out on reset.
a. Press the AUTO key to cancel the
pump operation. Press the Reset
button on the side of the pump motor
reducer. Press the AUTO key to
continue automatic operation.
- - -
b. The relay is malfunctioning.
b. Contact a Taylor service technician.
- - -
14.The piston travels back
and forth but product is
not being pumped.
a. Inspect the pump valve gasket.
a. The pump valve gasket must be
installed correctly, fit tightly, and not
have any holes or lubrication.
- - -
b. Inspect the O-rings.
b. O-rings must not be worn, torn, or fit
too loosely.
c. Check the pump cylinder.
c. The piston must be assembled
correctly and fit snugly in the pump
cylinder.
Problem
Probable Cause
Remedy
Page
Ref.
Содержание C706
Страница 8: ...1 4 TO THE INSTALLER Model C706 To the Installer 1 Notes ...
Страница 14: ...3 4 SAFETY Model C706 Safety 3 Notes ...
Страница 36: ...6 14 OPERATING PROCEDURES Model C706 Operating Procedures 6 Notes ...
Страница 42: ...8 4 TROUBLESHOOTING GUIDE Model C706 Troubleshooting Guide 8 Notes ...
Страница 44: ...9 2 PARTS REPLACEMENT SCHEDULE Model C706 Parts Replacement Schedule 9 Notes ...
Страница 48: ...10 4 LIMITED WARRANTY ON EQUIPMENT Model C706 Limited Warranty on Equipment 10 Notes ...
Страница 52: ...11 4 LIMITED WARRANTY ON PARTS Model C706 Limited Warranty on Parts 11 Notes ...