USER INTERFACE
5-3
Model C706
User Interface
5
AUTO Key
When the AUTO key is pressed, the indicator light shows
that the main refrigeration system is activated. In the
Auto mode, the Wash or Standby functions are
automatically canceled. The Mix Ref function is
automatically locked in to maintain the mix in the mix
hopper.
Note:
An indicating light illuminates and an audible
tone sounds when a mode of operation has been
pressed. To cancel any function, press the key again.
The indicator light and mode of operation will shutoff.
PUMP Key
When the PUMP key is pressed, the pump indicator light
comes on indicating the air/mix pump will operate as
required.
Beater Motor RESET Button
The RESET button is on the left side of the machine. A
reset mechanism protects the beater motor from an
overload condition. If an overload occurs, the reset
mechanism will trip. To reset the freezer, press the AUTO
key to cancel the cycle. Turn the power switch to the OFF
position. Press the
RESET button firmly.
CAUTION! DO NOT
use metal objects to press
the reset button.
Failure to follow this instruction may
result in electrocution.
Turn the power switch to the ON position. Press the
WASH key and observe the freezer’s performance. Open
the side access panel. Make sure the beater motor is
turning the driveshaft in a clockwise direction (from the
operator end) without binding.
If the beater motor is turning properly, press the WASH
key to cancel the cycle. Press the AUTO key to resume
normal operation. If the freezer shuts down again,
contact a service technician.
Air/Mix Pump Reset Button
The Reset button for the pump is located on the left side
of the machine. This protects the pump from an overload
condition. Should an overload occur, the reset
mechanism will trip. To reset the pump, press the Reset
button firmly.
Adjustable Draw Handle
The Model C706 features an adjustable draw handle to
provide the best portion control. The draw handle should
be adjusted to provide a flow rate of 5 oz. to 7-1/2 oz. of
product per 10-seconds. To increase the flow rate, turn
the screw clockwise. To decrease the flow rate, turn the
screw counterclockwise.
Figure 5-2
10354
Содержание C706
Страница 8: ...1 4 TO THE INSTALLER Model C706 To the Installer 1 Notes ...
Страница 14: ...3 4 SAFETY Model C706 Safety 3 Notes ...
Страница 36: ...6 14 OPERATING PROCEDURES Model C706 Operating Procedures 6 Notes ...
Страница 42: ...8 4 TROUBLESHOOTING GUIDE Model C706 Troubleshooting Guide 8 Notes ...
Страница 44: ...9 2 PARTS REPLACEMENT SCHEDULE Model C706 Parts Replacement Schedule 9 Notes ...
Страница 48: ...10 4 LIMITED WARRANTY ON EQUIPMENT Model C706 Limited Warranty on Equipment 10 Notes ...
Страница 52: ...11 4 LIMITED WARRANTY ON PARTS Model C706 Limited Warranty on Parts 11 Notes ...