 WARNINGS

This manual has been especially written for use by qualified installers. No information given 

in this manual can be considered as being of interest to end users. This manual is enclosed 
with digital programmer T-LINETD and may therefore not be used for different products!

Important information:

Disconnect the panel from the power supply before opening it.

The 

digital programmer T-LINETD has been designed to control an electromechanical gear 

motor for automating gates and doors of all kinds.

Any other use is considered improper and is consequently forbidden by current laws.

Please note that the automation system you are going to install is classified as “machine 

construction” and therefore is included in the application of European directive 2006/42/EC 

(Machinery Directive). This directive includes the following prescriptions:

-   Only trained and qualified personnel should install the equipment;

-   the installer must first make a “risk analysis” of the machine;

-   the equipment must be installed in a correct and workmanlike manner in compliance 

with all the standards concerned;

-   after installation, the machine owner must be given the “declaration of conformity”.

This product may only be installed and serviced by qualified personnel in compliance with 

current, laws, regulations and directives.

When  designing  its  products,  TAU  observes  all  applicable  standards  (please  see  the  at-

tached decla- ration of conformity) but it is of paramount importance that installers strictly 

observe the same stand- ards when installing the system.

Unqualified personnel or those who are unaware of the standards applicable to the “auto-

matic gates and doors” category may not install systems under any circumstances.

Whoever ignores such standards shall be held responsible for any damage caused by 

the system!

Do not install the unit before you have read all the instructions.

INSTALLATION

Before proceeding, make sure the mechanical components work correctly. Also 

check that the gear motor assembly has been installed according to the instructions. 

Then make sure that the power consumption of the gear motor is not greater than 

3A (otherwise the control panel may not work properly).

THE EQUIPMENT MUST BE INSTALLED “EXPERTLY” BY QUALIFIED PERSONNEL AS REQUIRED 

BY LAW.

Note: it is compulsory to earth the system and to observe the safety regulations that 

are in force in each country.

IF THESE ABOVE INSTRUCTIONS ARE NOT FOLLOWED IT COULD PREJUDICE THE PROPER 

WORKING ORDER OF THE EQUIPMENT AND CREATE HAZARDOUS SITUATIONS FOR PEO- 

PLE. FOR THIS REASON THE “MANUFACTURER” DECLINES ALL RESPONSIBILITY FOR ANY 

MALFUNCTIONING AND DAMAGES THUS RESULTING.

Содержание T-SIDETD

Страница 1: ...INSTALLATION GUIDE GUIDA ALL INSTALLAZIONE IT Istruzioni originali T SIDETD D MNL0TSIDETD 25 05 2023 Rev 09...

Страница 2: ...ed by qualified personnel in compliance with current laws regulations and directives When designing its products TAU observes all applicable standards please see the at tached decla ration of conformi...

Страница 3: ...e main menu Symbol Description Symbol Description Menu Power ok Down Recom mended stroke seutp Up Manual operating on Exit select work programs Enter Error alert Symbols shown in the inputs diagnostic...

Страница 4: ...sible to enable some options on the work pro grammes A No function B OPEN key key to open the door In order to assign the required function to the work programme it is first of all necessary to assign...

Страница 5: ...L sets the closing slowdown duration TCA adjusts the automatic closing time TRA OP adjusts the leaf delay time in opening for double leaf MASTER SLAVE TRA CL adjusts the leaf delay time in closing for...

Страница 6: ...ure the automation opens and re mains open until the mains voltage is restored DIP7 must be OFF OFF In the event of a power failure the automation performs the maneuvers normally 5 TCA INCREASE ON Wit...

Страница 7: ...MENU Options Language Change and select the desired language Language UsePasswordL0 ChangePswL0 UsePasswordL1 Italiano English Deutsch Francais Options Use password L0 Enables Disables the use of the...

Страница 8: ...edpassword successfully OPTIONS PERSONALIZZA TASTO P2 Through the Set key P2 function it is possible to enable some options on the work pro grammes A No function B OPEN key key to open the door In ord...

Страница 9: ...ETTINGS This menu gathers all the advanced parameters necessary to adjust the automation in detail To access it it will be necessary to press the keys P3 and P4 at the same time When changing one or m...

Страница 10: ...oor open Park CL adjusts the parking voltage with the door closed Push Go adjusts the manual push for automatic opening Ssoa OP Adjusts the operating area of the safety sensor in opening Parameters Ti...

Страница 11: ...ters Update procedure Setup procedure Performsthesetup ofmotionpro le Con rm Options Reset Parameters It allows the user to restore all parameters to factory conditions The basic parameters will be se...

Страница 12: ...tacle or check whether the leaf runs smo othly or not If necessary increase the power values through parameters Power OP and Power CL R3 No mains vol tage The automation wor ks in battery Check magnet...

Страница 13: ...sliding of the door If necessary increase the force values with the parame ters Power OP and Power CL G5 Encoder fault motor 2 Encoder fault check connections Make sure that the motor is moving that t...

Страница 14: ...14...

Страница 15: ...15...

Страница 16: ...0376 info tauitalia com www tauitalia com Foglietto illustrativo CARTA Raccolta differenziata Segui le indicazioni del tuo comune N B togliere i punti metallici Instruction leaflet PAPER Waste separat...

Отзывы: