Table 11 ‐ History of maintenance P07
Parameter Meaning
P7‐00
code of the service controller of the last entry to the setting
P7‐01
code of the service controller of the last but one entry to the setting
…
…
P7‐49
code of the service controller of the 49th entry to the setting
P7‐50
code of the service controller of the 50th entry to the setting
NOTE
If two entries to the counter setting occur with the same service remote controller, only one controller code
will be stored in the counter memory (there may not be two same entries stored in sequence).
2.1.13.
SERIAL NUMBERS OF PERIPHERAL DEVICES (CODE P10)
This function allows to show serial numbers of connected
electronic devices – see figure S/N 1600057. The change in the
electronic device configuration may be only made by a service
engineer. After an illegal exchange of any electronic device, as
mentioned in Table 12, the dispenser will be blocked and error
E80 to E84 will be displayed.
Table 12 – Table of peripheral devices P10
Parameter Meaning
P10‐1
Serial number of the processor unit
P10‐2
Serial number of the main displaying unit (master display)
P10‐3
Serial number of the auxiliary displaying unit (slave display)
P10‐4
Serial number of the unit of electromechanical totalizers
P10‐5
Serial number of the heat sensor unit (PDEINP)
P10‐6
Serial number of the mass meter
2.1.14.
OPERATING MODE OF THE DISPENSER (CODE P12)
This function defines the type of the operating mode of the dispenser.
Table 13 ‐ Operating mode of the dispenser P12
Parameter Meaning
P12 = 0
Automatic mode with dispenser remote control
P12 = 3
Manual mode
The parameter value may be 0 and 3.
If the parameter value
P12 equals 0
then the dispenser works in solely automatic mode, i.e. connected
to the control computer via a data line. The dispenser is completely controlled by a remote control unit
(PC, control counter, ...) – dispenser release for delivery, dispenser blocking, setting the product price
and maximum amount/volume for each delivery, etc. Shortly after interrupting communication
between the computer and the dispenser the display shows the error message E18. After
communication recovery, the E18 message disappears automatically.
If the parameter value
P12 equals 3
then the dispenser works in solely manual mode. The dispenser is
completely independent – not controlled remotely. The data line is blocked. Product unit prices are
Sn 1
600057
€
Kg
€/kg
P10-1