background image

Page 1 

 

 

TECHNICAL MANUAL 

 

 MODEL SKCRM1P AND SKCRM2P CREAM DISPENSERS 

 

 INSTALLATION, OPERATION AND MAINTENANCE   

 

Thank you for purchasing Silver King food service equipment.  Our goal is to provide our customers with the most reliable equipment in the 

industry today.  Please read this manual and the accompanying warranty information before operating your new Silver King unit.  Be sure to 

complete and mail the warranty card within 10 days of purchase to validate your warranty. 

 

Upon  delivery  of  your  new  Silver  King  unit,  inspect  the  carton  and  unit  for  shipping  damages.    Report  any  damage  immediately  to  the 

transportation  carrier  and  file  a  written  freight  damage  claim  to  protect  your  investment.    If  a  claim  is  to  be  filed,  save  all  packaging 

materials. 

 

INSTALLATION 

The stainless steel exterior of the cabinet has been protected by a plastic covering during manufacturing and shipping.  This covering can be 

readily  peeled  before  installation.    After  removing  this  covering,  wash  the  interior  and  exterior  surfaces  using  a  warm  mild  soapy  water 

solution and a sponge or cloth, rinse with clean water and wipe dry. 

 

Drip Tray: 

The Drip Tray is shipped inside the unit.  Install it as shown in the exploded view on the accompanying page. 

 

Location: 

When locating your cream dispenser, convenience and accessibility are important considerations, but the following factors must be observed: 

 

* When placing the unit on a counter,  the counter must be able to support a minimum of 100 pounds. 

 

  

* There must be at least two (2) inches of clear space above the unit, two (2) inches behind and open in front. 

 

* Correct serving height is important so that those using the dispenser can operate the dispenser properly. 

 

* The unit must be level.  The feet are adjustable to aid in leveling the unit.   If the feet are removed the unit will not operate properly   

   and the warranty will be void. 

 

* Avoid placing the unit next to an oven, heating element or hot air source which would affect the performance of the unit. 

 

Electrical Connections:

 

Be  sure  to  check  the  data  plate,  located  on  the  liner  of  the  cabinet,  for  required  voltage  prior  to  connecting  the  unit  to  power.    The 

specifications on the data plate supersede any future discussion. 

 

The  standard  dispenser  is  equipped  with  an  seven  (7)  foot  power  cord  that  requires  a  115  Volt,  60  Cycle,  1  Phase 

properly  grounded 

electrical receptacle.  The power cord comes with a 3 prong plug for grounding purposes.  Any attempt to cut off the grounding spike or to 

connect to an ungrounded adapter plug will void the warranty, terminate the manufacturers responsibility and could result in serious injury. 

 

The circuit must be protected with a 15 or 20 ampere fuse or breaker.

 

 

OPERATION 

Initial startup:

 

After satisfying the installation requirements, the cream dispenser is ready to start. The unit will start when the power cord is connected to a 

live electrical receptacle.  If the unit does not start when the power cord is plugged in, make sure that the switch on the back of the unit is in 

the ‘on’ position.  Allow the unit to run a minimum of two hours before loading it with product. 

 

Preparation For Use:

 

Once the unit has achieved proper operating temperature, observe the procedures noted in the label on the door liner for loading cream into 

the cream dispenser.  When removing an empty Cream Container, be sure to push the Valve Slide in fully before pulling the Dispensing Tube 

out of the valve.  It may be easier to remove or install the Dispensing Tube in the valve by removing the Valve Insert first then removing or 

installing the Cream Container.  The Dispensing Tube on a refillable Cream Container should be changed weekly.  The end of the tube may 

need to be cleaned daily with a clean cloth to prevent buildup which could affect the dispensing of product. 

 

Electronic Control Adjustment:

 

The electronic control used in Silver King portion control cream dispensers permits user access to parameters for the following functions: 

 

Содержание SKCRM2P

Страница 1: ...the unit next to an oven heating element or hot air source which would affect the performance of the unit Electrical Connections Be sure to check the data plate located on the liner of the cabinet for required voltage prior to connecting the unit to power The specifications on the data plate supersede any future discussion The standard dispenser is equipped with an seven 7 foot power cord that req...

Страница 2: ...ed whenever the walls accumulate a frost bank that is 1 2 inch thick To defrost the unit disconnect the power cord from the electrical receptacle and open the door After the frost has melted or come loose from the cabinet walls wipe out the cabinet interior Do not attempt to scrape or chisel off the frost as you could do irreparable damage to the unit MAINTENANCE Preventative maintenance is minima...

Страница 3: ...in tenths of seconds Press top button to increase middle button to decrease SKCRM1P large shot indicator SKCRM2P large shot indicator for right valve Adjustable large shot size in tenths of seconds Press top button to increase middle button to decrease Adjustable small shot size in tenths of seconds Press top button to increase middle button to decrease SKCRM1P not used SKCRM2P small shot indicato...

Страница 4: ...or for left valve Adjustable large shot size in tenths of seconds Press top button to increase middle button to decrease Temperature control cut in indicator Temperature control cut in value Changing value will change cabinet temperature proportionally Press top button to increase middle button to decrease Temperature control differential indicator Temperature control differential value Factory se...

Отзывы: