CNG dispensers TATSUNO EUROPE ‐ Quick User Guide
13
NOTE
Number of fuel products shown in the P03 parameter is conditioned by the configuration of the dispenser.
The identification system of delivery hoses and products is described in Figure 2. if you change the unit price, such
change will be reflected after a subsequent lift of the delivery nozzle.
NOTICE
Values set in the P03 parameter are valid
only in the dispenser manual mode.
If the dispenser is
connected to the central control system of the fuel station, then the fuel unit price is set directly by the control
system before each delivery. In such case the values of the P03 parameter are non‐functional.
NOTICE
The dispenser does
not enable deliveries with a zero value of the unit price.
In such case, after lifting
the delivery nozzle the dispenser display shows the error message E30 and the delivery does not start.
2.1.7.
CURRENT TIME AND DATE (CODE P04)
This function allows to show and set current time and date. The P04‐1 parameter shows and sets time in
the
“HHMMSS”
format (hours, minutes, seconds), the P04‐2 parameter shows and sets date in the
“DDMMYY”
format (day, month, year) ‐ example 15:35:11 24.12.2011. Setting is made by pressing the
<Ent>
key and entering the time/date in the correct format and confirming by the
<Ent>
key. You can
switch between time and date setting by pressing the
<+>
or
<‐>
key.
<+>
<‐>
Table 7 ‐ Description and setting of values of P04 parameter
Parameter Meaning
Factory setting
P04‐1
Time setting ‐ HHMMSS format (e.g. 124500 = 12:45:00)
0.00
P04‐2
Date setting ‐ DDMMYY format (e.g. 311216 = 31. 12. 2016)
1. 1. 2001
NOTE
The time and date information is used in P06 and P07 parameters for recording time of defect occurrence
and time of delivery finish.
NOTICE
48 hours after disconnecting the electrical power supply of the dispenser the internal clock will be reset.
Time and date values will switch to factory setting and must be set again!
2.1.8.
DISPLAYING THE PROGRAM VERSION AND CHECK SUMS (CODE P05)
This function shows the number of the program version of
the dispenser counter and different check sums. These
values are intended for metrology authorities and
authorized service engineers. The values may be only
displayed, not changed. You can browse values by using
<+>
or
<‐>
keys.
Time
124500
€
Kg
€/kg
P04-1
Date
311216
€
Kg
€/kg
P04-2
Info
4092
€
Kg
€/kg
P05-2