TATSUNO EUROPE a.s., www.tatsuno‐europe.com
12
2.1.4.
NON‐RESETTABLE TOTALIZERS (CODE P01)
Electronic totalizers for one or two delivery hoses (nozzles) are saved in the memory of the electronic
counter. These totalizers are
non‐resettable
and state what total amount of gas was delivered by
individual delivery hoses from the start of the dispenser operation.
Table 4 ‐ Description of values of P01 parameter
Parameter Meaning
P01‐1
amount of gas flown through the hose 1 in hundredths of kilogram (x 0.01kg)
P01‐2
amount of gas flown through the hose 2 in hundredths of kilogram (x 0.01kg)
NOTE
Number of totalizers of delivery hoses shown in the P01 parameter is conditioned by the configuration of
the dispenser. The identification system of delivery hoses and products is described in Figure 2.
2.1.5.
DAILY TOTALIZERS (CODE P02)
Electronic daily totalizers for all delivery hoses (nozzles) are saved in the memory of the electronic
counter.
These totalizers may be reset at any time by using the P15 parameter
(see description below).
They state what total amount of gas was delivered by individual delivery hoses from the moment of their
last resetting.
Table 5 ‐ Description of values of P02 parameter
Parameter Meaning
P02‐1
amount of gas flown through the hose 1 in hundredths of kilogram (x 0.01kg)
P02‐2
amount of gas flown through the hose 2 in hundredths of kilogram (x 0.01kg)
NOTE
Number of totalizers of delivery hoses shown in the P02 parameter is conditioned by the configuration of
the dispenser. The identification system of delivery hoses and products is described in Figure 2.
2.1.6.
PRODUCT UNIT PRICE (CODE P03)
This function allows to show and set the unit price of the product refilled (i.e. the price of one kilogram of
gas). A new unit price is shown on the display at the first lift
of the delivery nozzle and reset f the display if the dispenser
works in the
manual mode
. Setting is made by pressing the
<Ent>
key and entering the price in the
PPP
format and
confirming by the
<Ent>
key. The decimal point is not
entered. E.g. the price 26.50 Euro/kg is set as 2650, the
price 34,15 Euro/kg as 3415, etc. To switch for setting the
price for hose 2 press the
<+>
button. P03‐2 appears. By
pressing
<Ent> + PPPP + <Ent>
set the unit price for the hose 2.
Table 6 ‐ Description of values of P03 parameter
Parameter Meaning
Factory setting
P03‐1
product unit price hose 1
0.00 Euro / kg
P03‐2
product unit price hose 2
0.00 Euro / kg
SETUP
2650
€
Kg
€/kg
P03-1