CNG dispensers TATSUNO EUROPE ‐ Quick User Guide
11
2.1.3.
MANAGER MODE
The Manager mode is started by pointing the IR remote controller at the dispenser display (from the
distance of approx. 1 m from the dispenser display centre) a pressing the <
R
> key.
All delivery nozzles on
the dispenser must be hung in advance and the sale on
the dispenser must be finished (paid).
After calling up the
Manager mode the dispenser display shows a prompt for
entering the 4‐digit access password:
Due to keeping the password confidential the digits
entered are shown as dashes. The following default access
password is set in the factory: “1111”.
Example:
Press <
1
><
1
><
1
><
1
> and <
ENT
> keys
NOTE
If the fuel station manager forgets the valid access password then he/she must contact the authorized
service staff who can set a new one.
After entering the valid access password, the display shows
the value of the first parameter 01. Now it is possible to
browse parameters by using the <
>
> key or by entering the
number of searched parameter
and confirm with the
<
ENT
> key to go directly to the desired parameter.
The Manager mode allows to view and change the values of
parameters listed below ‐ see Table 3.
Table 3 ‐ List of parameters in the Manager mode
Parameter Description
01
Non‐resettable volume totalizers
02
Daily volume and financial totalizers (resettable)
03
Product unit prices (in manual mode)
04
Current time and date
05
Program version and check sums
06
Error message history
07
Latest delivery history
08
Access password for the Manager mode
09
Maintenance history
10
Serial numbers of connected electronic units
11
‐ reserved ‐
12
Dispenser controlling mode
13
Defects statistics
14
Current operating temperature
15
Resetting daily totalizers
The Manager mode is finished by pressing
<R>
or
<A>
keys. The mode is also finished automatically if no
remote controller button is pressed for 60 seconds.
----
€
Kg
€/kg
Code
tot
317890
€
Kg
€/kg
P01-1