22
TARGET ECO I FEEDING, rev.09
TARGET ECO I FEEDING
5.4.2
Relay Assignment for the
Actuator
If the drops are controlled by an actuator,
you must assign an actuator position to each
ration. The following procedure show how
to make this assignment and how to assign
the actuator’s open and close relays.
Select:
11. Installation *
2. Relay Assignment
6. Actuator **
*
Accessible from the installer mode (s. 5.2).
*
Accessible if the actuator is enabled (s. 5.3).
•
Ration #X Actuator Position:
Specify the actuator position that is asso-
ciated with the delivery of each type of
ration as follows:
1. Open the actuator to a position that is
used for the distribution of a ration (use
the bypass switches of your relay panel to
open the actuator).
2. Once the actuator is correctly posi-
tioned, assign its position to the proper
ration. The current actuator position is dis-
played below.
3. Repeat for each ration in use.
Relay Assignment – Actuator
Exit: Press BACK
Change: Press Modify
Press to Select an item
Ration #1 – Actuator position:
0
Ration #2 – Actuator position: 50
Ration #3 – Actuator position: 100
Current actuator position: 0
Open Actuator – Module ID
3
– Output #
7
Close Actuator – Module ID
3
– Output #
7
Hysteresis: 3 %
•
Current actuator position:
This is the current position of the actuator’s
potentiometer. Use it as a reference to
assign an actuator position to each ration.
•
Open / Close actuator
Module ID:
Select on which relay panel the actuator’s
opening and closing relays are located. The
relay panel is identified by its ID number
(ID #2 to ID #19). Tables are also avail-
able at the end of this manual to write down
the identification number of each panel.
•
Open / Close Actuator
Output #:
Select which relays of the relay panel are
used to open and to close the actuator (out-
puts 1-16). If a device is connected to re-
lays 17-32 of a 32-output relay panel, se-
lect to which relay of the second 16-relay
strip this corresponds (i.e., relay 17=1,
relay 18=2... relay 32=16. Refer to sec-
tion 5.4 for further information).
•
Hysteresis:
The hysteresis is the acceptable offset in
the actuator’s position. It can be adjusted
from 0 to 4%.
23
TARGET ECO I FEEDING, rev.09
TARGET ECO I FEEDING
5.5
Version
This menu shows the version number of
your controller program. This piece of in-
formation is useful to get technical sup-
port.
Select:
11. Installation*
3. Version
*
Accessible from the installer mode (s. 5.2).
Exit: Press BACK
ECO I Feeding
SETTINGS V. X.X
PCXX