extended at +90% servo motion. The servo will ‘stall’ if commanded outside this range, and
stalling is hard on a servo. We can limit the range that
CH3
can command to prevent servo stall.
Page down thru the Model Setup menu to the
OUTPUTS
screen. With default settings your
outputs screen should look like this:
Your OUTPUTS screen now looks like this:
Full upward throw on the Throttle stick axis will now provide only 90% of full upward servo
motion, and full downward throw will provide only 75% of downward servo motion. No servo
stall!
The
OUTPUTS
screen allows direct limiting of the motion range commanded on
each side of the motion center point. Here we will limit servo motion to 75% of
normal below the center point and 90% above.
Use the scroll wheel to highlight the
CH3
line, then tap the
ENTER
button to
bring up an action menu.
Tap
ENTER
to enter the
EDIT
screen.
Scroll down to the
Min
line, tap ENTER, scroll to
-75.0
and tap
ENTER
.
Scroll down to the
Max
line, tap ENTER, scroll to
90.0
and tap
ENTER
.
Tap
EXIT
twice.