5.1.1
Front Panel Layout
Figure 5.1 Delta-Star transformer front panel layout
Ref
Item
Function
A
Mains outlet - 4 wire
400V 4 wire output to 200A-3PH mk2
B
3 phase output fuses
Three phase output fuses
C
Single phase output
230V single phase output for DVS3
D
Single phase output fuse
Fuse for single phase output
E
Single phase input fuse
Fuse for single phase input
F
Earth terminal
Connection to local earth
G
Three phase input fuses
Three phase input fuses
H
Mains input
– three wire
115V-440V three wire input
J
Input voltage selector keyswitch
Input voltage selector switch
K
Mains on/off indicator
Lit when power is on
L
Mains on/off switch
Isolate unit from mains
5.1.2
Electrical Specification
5.1.2.1 Supply Requirements
The input to the delta-star converter is a 3 wire three phase supply. The input may be
switched to one of the following voltages:
•
115V
10% 3 phase 3 wire 1500VA max
•
230V
10% 3 phase 3 wire 1500VA max
•
400V
10% 3 phase 3 wire 1500VA max
•
440V
10% 3 phase 3 wire 1500VA max
5.1.2.2 Three Phase Output
A three phase output is provided to supply the 200A-3PH mk2. Do not connect any other type
of equipment to this output.
Voltage:
400V
10%
Type:
4 wire 3 phase isolated from mains
Rating:
200VA continuous/600VA 1 min on/15 min off
D
E
C
B
A
F
H
J
J
K
L
G