19
Timer information
Timer range
0-999.999s/9999.99s/99999.9s auto-ranging
Resolution
1ms/10ms/100ms
Accuracy
0.01% rdg
2d All modes except current operated
0.01% rdg
4d Current operated mode
Contact o/c voltage
24V
Contact s/c current
20mA
Contact indication
LED on
– contact open
LED off
– contact closed
Timer Modes
Timer Mode
Timer Start
Condition
Timer Stop
Condition
Automatic
output off
Example
application
Off
-
-
-
Set current
Internal Start
Main output on
C1 change
When timer
stops
IDMT relay
1 Contact using
Contact 1
C1 1
st
change
C1 2
nd
change
C1 1
st
change
(timer start)
Auto-reclose
relay
1 Contact using
Contact 2
C2 1
st
change
C2 2
nd
change
C2 2
nd
change
(timer stop)
Drop-off timing
2 Contacts
1st change C1
C1 change
C2 change
C2 change
(timer stop)
2 Contacts
1st change C2
C2 change
C1 change
Output cycles
on and off
Multiple auto re-
close timing
Current
Operated Phase
Select*
Current >20% of
range
Current <20% of
range
Current <20%
Timer stop
Miniature circuit
breakers
Pulse
Main output on
500ms
500ms
Set current for
thermal devices
* results obtained with test currents below 20% of range will give a lower accuracy than
specified.
The timer is automatically reset in every mode when the output is switched on. In each mode
that the timer is active, the output of the unit must be switched on to arm the timer.
Each contact channel has a contact input for volt-free contacts and a Vdc input for dc
voltages. The Vdc input may be used to trigger the timer from a dc voltage, and will trigger
from either the voltage switching from zero to 24-240Vdc or 24-240Vdc to zero. The voltage
must be connected with positive to the red “VDC” terminal and negative to the blue “COM”
terminal.