36
Hardware Installation
3. Connect a power cord to the outlet on the power supply at the back of the library.
4. Power on the library by turning on the rear power switch.
5. Power up the host system.
6. Verify communication with all devices on the bus.
7. Configure your library using the commands on the front panel. For configuration information,
please refer to
Configuring the Library
.
Warning
Make sure the AC outlet that you connect the StorageLibrary power cable into is
reliably earthed.
Adding the StorageLibrary to an existing rack installation can cause a leaking
current fault condition because of the summation of the leaking currents.
For safety, a 250V 2A fuse is located near the power switch.
Note
Tandberg Data recommends that all external SCSI devices, including the
StorageLibrary, are powered on before the computer system is re-started (Steps
5 and 6 above).
Connecting SAS Cables
Follow this procedure if you are installing a library that includes SAS tape drives.
Figure 24. StorageLibrary Cabling (SAS interface)
1. If your library includes tape drives with SAS interface, connect SAS cables to the tape drives.
Attach one end of the SAS cable to the SAS port on each drive. Attach the other end of the cable
to the host.
2. Connect your Ethernet cable to the Ethernet port on the back of the library for remote access to
the library via the remote management interface. Push the cable until it snaps into place. Connect
the other end to a normal 10/100 BaseT Ethernet outlet.
3. Connect a power cord to the outlet on the power supply at the back of the library.
4. Power on the library by turning on the rear power switch.
5. Power up the host system.
6. Verify communication with all devices on the bus.
7. Configure your library using the commands on the front panel. For configuration information,
please refer to
Configuring the Library
.