5.6. Settings for the switching inputs
Name
No.
Input values
(Default)
Remarks and tips
Assignment of the
functions to the
switching inputs
F0 … F7
F0
1
F1
2
F2
4
Switching input 1
105
1 … 255 (0)
F3
8
F4
16
Switching input 2
107
1 … 255 (0)
F5
32
F6
64
F7
128
Assignment of the
functions to the
switching inputs
F8 … F15
F8
1
F9
2
F10
4
Switching input 1
106
1 … 255 (0)
F11
8
F12
16
Switching input 2
108
1 … 255 (0)
F13
32
F14
64
F15
128
Minimum switch-
on time of the
switching inputs
= Time period for which the input remains
at least on after it has been connected to
ground.
Increasing the input value by "1" extends
the time period by 0.1 sec.
0 = 0 sec. (off)
255 = 25.5 sec.
Switching input 1
97
0 … 255 (0)
Switching input 2
98
0 … 255 (0)
Example:
The shunting gear (here switched with F3) is to be activated automatically for the duration of the crossing
over a switch road (here 10 seconds).
CV 105 = 8 (assignment of the switching input 1 to F3)
CV 97 = 100 (= 10 seconds)
Configuration variables and registers | 51