LD-G-43
5.8. Settings for driving operation
Setting the Packet Time Out
Name
No.
Input values
(Default)
Remarks and tips
Packet Time Out
11
2 … 255 (16)
Time period between the failure of the
digital signal and the change to the
alternative operation (analogue operation).
Increasing the input value by "1" extends
the time period by 10 ms.
Notes:
If automatic analogue recognition is active, the decoder will automatically switch to analogue mode if it
does not receive a digital signal during the set time.
If the decoder is supplied via a buffer circuit,
- the automatic analogue recognition in CV 29 should be deactivated and
- a low value for the Packet Time Out should be set (approx. 16).
This prevents the locomotive from continuing to run unplanned after the track voltage has been switched
off (e.g. during an emergency stop or a signal stop).
Consist operation
As a standard, in multiple units (consist operation) you can only control velocity and direction.
In CV 21 and 22 you can define additional functions to be switched when using the address for
multiple units defined in CV 19. If the value "0" is set, the function will continue to be
addressed only via the address set for the vehicle concerned in CV 1 or CV 17 and 18.
Name
No.
Input values
(Default)
Remarks and tips
Functions active in
consist
operation
(F1 to F8)
21
0 ... 255 (0)
F1 on
1
F2 on
2
F3 on
4
F4 on
8
F5 on
16
F6 on
32
F7 on
64
F8 on
128
Functions active in
consist
operation
(F0, F9 to F12)
22
0 ... 63 (0)
F0f on
1
F0r on
2
F9 on
4
F10 on
8
F11 on
16
F12 on
32
Configuration variables and registers | 53