LD-G-43
t
a
ms elektronik
Effects of the function outputs
Kicking
: The output first receives full voltage for a maximum of
approx. 25.5 seconds and is then switched off.
Assignment separately for each output. Setting the kick time
(= time during which the maximum voltage is applied to the output)
together for all outputs to which the function is assigned.
Application example: Some types of electrical couplings require full
voltage for decoupling. After uncoupling, however, the voltage is
switched off to protect the couplings.
CV programming
CV 55...62
CV 99
Successive dimming up and down
: The voltage at the output is
gradually increased when switched on or gradually reduced when
switched off.
Assignment separately for each output. Setting the time duration for
dimming up and down together for all outputs to which the function
is assigned.
Application example: Simulation of old oil or incandescent lamps.
CV programming
CV 55...62
CV 100
Fire simulation
: The voltage at the output is reduced / increased
in short, irregular intervals, connected LEDs or lamps produce the
flickering light typical for an open fire. Assignment separately for
each output.
Application example: Simulation of the fire in the firebox of steam
locomotives.
CV programming
CV 55...62
On/Off
at a defined limit voltage (speed): By default, the output is
switched off when the limit voltage is exceeded and switched on
again when it falls below. The function can be reversed by inverting
the function.
Assignment separately for each output. Setting the limit voltage
together for all outputs to which the function is assigned.
Application example: automatic switching on and off of the driver's
cab lighting at a certain limit voltage.
CV programming
CV 55...62
CV 63
18 | Operation overview