Name of CVs /
registers
No. Input value
(Default)
Remarks and Tips
Dimming depending
on the speed level
= reduction of the voltage at
the output
"1" = lowest voltage
"255" = maximum voltage
Values are applied to the outputs
determined in CV#114 and starting from a
speed level determined in CV#113 only.
AUX1
123 1...255
(255)
AUX2
124
AUX3
125
AUX4
126
Shunting light
Name of CVs /
registers
No. Input value
(Default)
Remarks and Tips
Shunting light 131 0 ... 255
(0)
for AUX1
1
for AUX2
2
for AUX3
4
for AUX4
8
for AUX5
16
for AUX6
32
to be switched with F3
64
to be switched with F4
128
Example: For AUX2 and AUX 3 shunting light, to be switched with F4:
à
input value: 134 (= 2 + 4 + 128)
Kick function
Name of CVs /
registers
No. Input value
(Default)
Remarks and Tips
Kicking time
for direction
"forward"
162 0 ... 255
(32)
0 = short
255 = long
Kicking time
for direction
"backward"
163
Page 43