Operator Manual
3–36
Comp Switch 5
This switch determines the printer response to formatted print lines composed
entirely of unprintable characters (such as Control and Format commands). If
OFF, and the Ignore bit in the PCIA is ON, the line is not printed and no NL
function is performed. If ON, the printer prints a blank line in response to a line
of unprintable characters and performs an NL function.
Comp Switch 6
This switch determines the printer response to an FF command according to
where it is located in the data stream. If OFF, the printer performs an FF
function only if the FF command is at the first print position or at the right
margin plus one column. FF commands at any other location are treated as
blanks. If ON, the printer recognizes FF commands any time they are part of
a data stream.
Comp Switch 7
This switch determines printer response to an FF command and works in
conjunction with Comp Switch 4. If OFF, and the FF command is the last byte
in a print order, the printer responds according to how Comp Switch 4 is set. If
the FF command is not the last byte in the print data and the current print
position is not already at Column 1, the printer performs an NL function at the
end of the print job. If ON, the printer performs an FF function after each print
job if the print position is not at the top of form.
Comp Switch 8
This switch determines the printer response to a FF command in conjunction
with Compatabilty Switch 7. The default is OFF.
OFF After all the data in a print job has been printed, a NL or a FF command
is performed according to the setting of Compatability Switch 7.
ON
The printer performs a FF function after an operator-initiated local copy
(e.g., a Print Screen Command from the operator). This switch over-
rides Compatability Switch 7 when it is turned on.
IR Delay (Coax Only)
This parameter defines the delay from the time a fault is reported on the printer
control panel until it is reported to the host. This is used primarily to allow you
to change paper before the host cancels the print job. The default is 10 min-
utes.
Hex Passthrough
When you set this parameter to On, the printer translates certain EBCDIC
character streams into ASCII escape sequence commands, and executes the
commands. Details can be found in the Twinax / Coax Applications Manual.
Default is off.
IPDS: This option is not available.