③
Caution
Refer to the detection area chart, and select the installation
location. Then, check the actual operation, and adjust the
appropriate area.
Perform the operation check after installation and also on
periodic basis to make sure that there is no problem in the
operation.
Install the unit in the
location where the
detection area faces toward
a place that intruders may
pass through.
After installation, make
sure to adjust the detection
area and perform sufficient
operation check.
This unit is for wall mounting. When installing it on poles,
ceilings, or under eaves, use the specified attachments (sold
separately).
This unit has a rainproof structure, not a waterproof
structure. Do not hose it directly. Do not use the unit in
places subject to water and/or constant high humidity, such
as bathroom. Failure to follow this could result in
malfunction.
Avoid operation in places where there is not enough space
for the detection area to pass through without being
obstructed. It may cause false or lost detection.
When this operation is obliged, selecting "high density
mode" is recommended.
Note, however, that the performance to prevent
malfunction against environmental change and small
animals will be reduced with this mode.
In order to maintain the rainproof structure of this unit,
mount it in the correct direction. Mounting it sideways or
upside down may result in malfunction.
Apply caulking to wiring holes based on the mounting wall
material, if necessary, in order to maintain rainproof
performance.
Mount the unit straight so that it does not look inclined
from the front and side view.
When mounting on the wall, adjust the detection area so
that it does not cover the wall surface. It may cause false
or lost detection.
Move the detection area horizontally by one step or more
to keep it away from the wall.
Adjust the detection area
so that it does not go
beyond the site.
(Unexpected objects may
be detected)
'(7(&7,21$5($
Please pay attention that the detection distance changes by
below factors
* Mounting height
(The higher installation position, the longer detection
distance becomes)
* Inclination in the grand in detection area
The configuration of detection area based on the level ground.
In case of inclined ground, the detection distance becomes
long in the downslope, the detection distance becomes short
in the upslope.
And it is impossible to configure the proper detection area in
where there are in inclined or stepped ground in detection area.
There is a possibility that the false or lost detection occur under
this situation.
Please check the proper position in each detection zone using
LED aiming function and do the operation check by walking test.
Mounting height:2.0m
Detection distance:40m
Mounting height:2.0m
Detection distance:20m
※Adjust the mounting height of the
sensor using the center of the
sensor housing as a guide.
※
7KHULJKWDQGOHIWDX[LOLDU\]RQHLQ
QHDUGHWHFWLRQDUHDEHFRPHV
HIIHFWLYHZKHQWKHDUHDPDVNLQJ
SODWHLVUHPRYHG
1°
80°
3.2m(10.5 )
1.1m(3.5 )
1.1m(3.5
)
0.9m(3
)
0.3m(1
)
1.4m(4.5
)
2m
(6.6 )
5m
(16 )
10m
(33 )
15m
(49 )
20m
(66 )
25m
(83 )
30m
(100 )
35m
(115 )
40m
(135 )
0
Auxiliary zone
CENTER ZONE
【Top view】
【Top view】
【Side view】
【Side view】
83°
3°
1.0m(3.5
)
0.5m(1.5
)
1.6m(5.5 )
0.6m(2 )
0.6m(2
)
0.6m(2
)
2m
(6.6 )
5m
(16 )
10m
(33 )
15m
(49 )
20m
(66 )
0
CENTER ZONE
Auxiliary zone
:DOO
VXUIDFH
:DOO
VXUIDFH
:DOO
VXUIDFH
6HQVRU
6HQVRU
6HQVRU
'HWHFWLRQ
DUHD
'HWHFWLRQDUHD
'HWHFWLRQDUHD
In case of the detection along the wall, adjust the detection
area by noting the following points.
:DOOIHQFHHWF