Vertical adjustment

Horizontal adjustment

Wall mount

HORIZONTAL
ADJUSTMENT

VERTICAL
ADJUSTMENT

(1) Loosen cover locking 

screw to detach cover.

(4)After adjustment is completed, lightly push head unit. 

It will replace to the armed position automatically. 

When head unit is placed at 
testing position, alarm LED lights 
and alarm output continuously 
outputs 
(Trouble alarm).

(3) Adjust the coverage by moving the mirror so that LED on 

the head unit is visible through mirror from location to be 
protected.

Adjust the coverage 
so that center of 
sensitive zone 
should be positioned 
at human waist 
height.

(2) Slide the head unit to bring the sensor unit into aiming 

position. 
Slip to the arrow direction and it will be automatically 
locked at testing position.

(Ex.) In case of 13' (4m) wall mount height and 55' 

(16.8m) range, selector should be set at 5.

Coverage can be adjusted by turning area selector in accordance with area set chart on the back 
of sensor unit.

Loosen base unit locking screw and rotate sensor unit horizontally for adjustment.

ADJUST UNDER AIMING POSITION

DISTANCE

ft. m

WALL

6.5
8.5

10
13

2.0
2.6
3.0
4.0

4
6
8

11

25

7.6

33

10.0

40

12.0

45

13.7

55

16.8

60

18.3

66

20.0

75

22.8

82

25.0

3
5
6
9

3
4
5
7

2
4
5
6

2
3
4
5

2
3
4
5

1
2
3
4

1
2
3
4

1
2
3
4

Insert screwdriver in the 
base locking hole and loosen 
the locking screw. 
Adjust by rotating sensor 
unit. After adjustment, 
tighten the locking screw.

Hold the parabolic mirror 
with hard and rotate it for 
adjustment. 
Do not touch the mirror 
face.

Hold the parabolic mirror 
with both hands push 

△△△

 

portion for horizontal fine 
tuning.
 (When wall mounted, this 
is horizontal adjustment.)

LIGHTS RED

INVISIBLE

INVISIBLE

VISIBLE

Indicator

4

5

13' (4m)

10' (3m)

6.5' (2m)

16'

(4.9m)

33'

(10m)

55'

(16.8m)

0

5

Protrusion

Protrusion

When operation check shows improper area setting, visually 
check its area setting.

ADJUSTMENT OF THE FIELD VIEW

Содержание PA-5312E

Страница 1: ...or damage to the unit if the unit falls as well as prevent the sensor from being tampered Mount the unit on a solid ceiling or wall surfaces where reinforcement materials are used If you mount the unit on non wood materials of plaster board or concrete securely mount it using anchors and mounting screws that match the wall materials Unstable mounting may result in injury and or property damage if ...

Страница 2: ...n electric shock fire and or malfunction Do not install the unit in places subject to oil smoke or steam high humidity and or a lot of dust Electricity that travels through these substances may result in fire electric shock and or false operation Ask qualified personnel for any electrical work necessary for installation if required Failure to follow this may result in fire and or electric shock Th...

Страница 3: ...ill come off easily Attach the base unit with the arrow pointing to the direction of ceiling Refer to 5 WIRING and connect terminals Twist cover counter clockwise while pushing cover locking lever as the figure to detach cover Snap off limit pin near the parabolic mirror which release the mirror to turn to wall mount area Set area by area selector Put the cover on the channel of cover spacer acces...

Страница 4: ...t 1160m 22000ft 6700m 5900ft 1800m 34000ft 10400m AWG 22 Dia 0 65mm AWG 18 Dia 1 0mm AWG 16 Dia 1 25mm 9300ft 2840m 55000ft 16500m 6 AREA SETTING PA 5312E Indicator Ceiling mount Ceiling mount Wall mount PA 5325E Ex In case of 10 3m ceiling mount height and 40 12m range selector should be set at E Ex In case of 13 4m wall mount height and 33 10m range selector should be set at 9 Ex In case of 10 3...

Страница 5: ...5 Coverage can be adjusted by turning area selector in accordance with area set chart on the back of sensor unit Loosen base unit locking screw and rotate sensor unit horizontally for adjustment ADJUST UNDER AIMING POSITION DISTANCE ft m WALL 6 5 8 5 10 13 2 0 2 6 3 0 4 0 4 6 8 11 25 7 6 33 10 0 40 12 0 45 13 7 55 16 8 60 18 3 66 20 0 75 22 8 82 25 0 3 5 6 9 3 4 5 7 2 4 5 6 2 3 4 5 2 3 4 5 1 2 3 4...

Страница 6: ...TACT CHENGEOVER SETTING OF SENSITIVITY SLIGHT MOTION DETECTION Switch 3 ON N O OFF N C Factory set Switch 6 ON Slight motion OFF Intruder detection Factory set Change alarm contact to N O when sensor is used for an application except security purpose such as light control When operation check shows you high sensitivity of sensor change setting of sensitivity with mode selector and re check operati...

Страница 7: ...it The detector reacts to passersby outside Remove the cause Change the installation location Change the installation location Shield sunrays with a blind Readjust the detection area Alarm LED lights though connected units are inactive Poor contact output connection or broken wire Check the wiring Connected units are damaged Check connected units Damaged alarm contact Check alarm output terminals ...

Страница 8: ...mm 2 31 59 3 26 83 5mm Ceiling mount Wall mount Mounting hole Ceiling mount horizontal angle adjustment Vertical angle adjustment Sensor locking screw Cover locking screw Silver White 0 18 4 5m m 25 45 30 9 0 2 0 φ7 49 φ192mm φ6 63 φ170mm 0 27 7mm 2 03 52mm 1 60 41mm 1 40 36mm Flush mount attachment BU 5300 Sensor unit Plate Flush mount box Mounting hole 8 Limited Warranty TAKEX products are warra...

Отзывы: