EXTERNAL DIMENSIONS 

10

SPECIFICATIONS

 

Passive infrared sensor

 PA-5312E 

PA-5325E

 

Passive infrared (QUAD)

  Wide angle protection 
 

40' (12m) Max.    

 

72 ( 18 pairs ) 

24 ( 6 pairs )

 

9.5 to 30V DC (non-polarity)

 25mA 

Max. (N.C. / N.O. contact)

 

Dry contact (Semi-Conductor)

 Reset : Approx. 2 sec. (N.C. / N.O. SELECTABLE)
  24V (AC/DC) 0.25A Max. (protective resistor 3.3

Ω

)

 

Dry contact (type N.C.)

 

Open when cover or body is detached

 

30V DC 0.1A Max.

 

3min. -Flickering, 47min. -Lighting

  Sensitive zone : 36 pairs 

Sensitive zone : 12 pairs

 Red 

LED

 

Flickering (every 0.5 sec.) : Warming-up

 

Lighting (approx.2sec.) : Alarm

  Flickering (every 0.25 sec.) : Trouble indication
 

Continuous lighting : Trouble alarm

 

(Disabled is LED except trouble indicaiton)

 

Yellow LED

 

Flickering : Memory activated

 

Lighting    : Memory indicated

  Unit trouble : Monitoring inner circuit and wiring damage
                     Operation : Trouble alarm
  Low voltage trouble : Monitoring low voltage
                     Operation : Trouble alarm
  Positioning trouble : Monitoring failure to replace view finder
                     Operation : Trouble alarm

 

14

°

F to 

131

°

F (without dewdrops) 

 

(−

10

°

C to 

55

°

C)

 

Indoor (ceiling / wall)

 Terminals

 

8.75 oz (250g)

 

Body : ABS resin   Cover : PE resin

  Ceiling mount : Vertically 26

°

Horizontally 

±

15

°

  Wall mount     : Vertically 20

°

Horizontally 

±  

5

°

Model

Detection system

Coverage

Sensitive zone

Supply voltage

Current consumption

Alarm output

Tamper output

Alarm memory

Slight motion detection

Alarm LED

Memory LED

 

Troble signal

Ambient temperature 
range

Mounting position

Wiring connections

Weight

Appearance

Adjustment range

Vertical curtain protection 

82' (25m)Max.

■OPTIONAL 

φ5.75"

(φ147.3mm)

φ1.17"(φ30mm)

Wiring hole

6-φ0.17"

(φ4.2mm)

2.50"

(64mm)

PCDφ2.60"

(φ66.7mm)

φ5.75"

(φ147.3mm)

2.31"

(59)

3.26"

(83.5mm)

Ceiling mount

Wall mount

Mounting hole

Ceiling mount horizontal 

angle adjustment

Vertical angle 

adjustment

Sensor locking screw

Cover locking screw

(Silver)

(White)

0.18"

4.5mm

25°

45°

30°

(90°

20°

φ7.49"

(φ192mm)

φ6.63"(φ170mm)

0.27"

(7mm)

2.03"

(52mm)

1.60"

(41mm)

1.40"

(36mm)

Flush mount attachment  [BU-5300]

Sensor unit

Plate

Flush mount box

(Mounting hole)

8

Limited Warranty :

TAKEX products are warranted to be free from defects in material and workmanship for 12 months from original date of shipment. Our warranty does not cover 
damage or failure caused by natural disasters, abuse, misuse, abnormal usage, faulty installation, improper maintenance or any repairs other than those provided 
by TAKEX. All implied warranties with respect to TAKEX, including implied warranties for merchantability and implied warranties for fitness, are limited in 
duration to 12 months from original date of shipment. During the Warranty Period, TAKEX will repair or replace, at its sole option, free of charge, any defective 
parts returned prepaid. Please provide the model number of the products, original date of shipment and nature of difficulty being experienced. There will be 
charges rendered for product repairs made after our Warranty Period has expired.

No.04-498   1506

In Japan

Takex America Inc.

4/15 Howleys Road, Notting Hill,
VIC, 3168
Tel  : +61 (03) 9544-2477
Fax : +61 (03) 9543-2342

Takenaka Engineering Co., Ltd.

83-1, Gojo-sotokan, 
Higashino, Yamashina-ku, 
Kyoto 607-8156, Japan 
Tel  : 81-75-501-6651
Fax : 81-75-593-3816
http : // www. takex-eng. co. jp /

Takex America Inc.

151 San Zeno Way 
Sunnyvale,
CA 94086, U.S.A
Tel  : 408-747-0100
Fax : 408-734-1100
http : // www. takex. com

Takex Europe Ltd.

Aviary Court, Wade Road,
Basingstoke, Hampshire. RG24 8PE, U.K.
Tel  : (+44) 01256-475555
Fax : (+44) 01256-466268
http : // www. takex. com

In the U.S.

In the U.K.

In Australia

Содержание PA-5312E

Страница 1: ...or damage to the unit if the unit falls as well as prevent the sensor from being tampered Mount the unit on a solid ceiling or wall surfaces where reinforcement materials are used If you mount the unit on non wood materials of plaster board or concrete securely mount it using anchors and mounting screws that match the wall materials Unstable mounting may result in injury and or property damage if ...

Страница 2: ...n electric shock fire and or malfunction Do not install the unit in places subject to oil smoke or steam high humidity and or a lot of dust Electricity that travels through these substances may result in fire electric shock and or false operation Ask qualified personnel for any electrical work necessary for installation if required Failure to follow this may result in fire and or electric shock Th...

Страница 3: ...ill come off easily Attach the base unit with the arrow pointing to the direction of ceiling Refer to 5 WIRING and connect terminals Twist cover counter clockwise while pushing cover locking lever as the figure to detach cover Snap off limit pin near the parabolic mirror which release the mirror to turn to wall mount area Set area by area selector Put the cover on the channel of cover spacer acces...

Страница 4: ...t 1160m 22000ft 6700m 5900ft 1800m 34000ft 10400m AWG 22 Dia 0 65mm AWG 18 Dia 1 0mm AWG 16 Dia 1 25mm 9300ft 2840m 55000ft 16500m 6 AREA SETTING PA 5312E Indicator Ceiling mount Ceiling mount Wall mount PA 5325E Ex In case of 10 3m ceiling mount height and 40 12m range selector should be set at E Ex In case of 13 4m wall mount height and 33 10m range selector should be set at 9 Ex In case of 10 3...

Страница 5: ...5 Coverage can be adjusted by turning area selector in accordance with area set chart on the back of sensor unit Loosen base unit locking screw and rotate sensor unit horizontally for adjustment ADJUST UNDER AIMING POSITION DISTANCE ft m WALL 6 5 8 5 10 13 2 0 2 6 3 0 4 0 4 6 8 11 25 7 6 33 10 0 40 12 0 45 13 7 55 16 8 60 18 3 66 20 0 75 22 8 82 25 0 3 5 6 9 3 4 5 7 2 4 5 6 2 3 4 5 2 3 4 5 1 2 3 4...

Страница 6: ...TACT CHENGEOVER SETTING OF SENSITIVITY SLIGHT MOTION DETECTION Switch 3 ON N O OFF N C Factory set Switch 6 ON Slight motion OFF Intruder detection Factory set Change alarm contact to N O when sensor is used for an application except security purpose such as light control When operation check shows you high sensitivity of sensor change setting of sensitivity with mode selector and re check operati...

Страница 7: ...it The detector reacts to passersby outside Remove the cause Change the installation location Change the installation location Shield sunrays with a blind Readjust the detection area Alarm LED lights though connected units are inactive Poor contact output connection or broken wire Check the wiring Connected units are damaged Check connected units Damaged alarm contact Check alarm output terminals ...

Страница 8: ...mm 2 31 59 3 26 83 5mm Ceiling mount Wall mount Mounting hole Ceiling mount horizontal angle adjustment Vertical angle adjustment Sensor locking screw Cover locking screw Silver White 0 18 4 5m m 25 45 30 9 0 2 0 φ7 49 φ192mm φ6 63 φ170mm 0 27 7mm 2 03 52mm 1 60 41mm 1 40 36mm Flush mount attachment BU 5300 Sensor unit Plate Flush mount box Mounting hole 8 Limited Warranty TAKEX products are warra...

Отзывы: