3
●
Top view
Vertical curtain protection
Max. coverage when ceiling mounted.
Installation height 10' (3m) : SETTING [C]
Min. coverage when ceiling mounted.
Installation height 10' (3m) : SETTING [H]
Min. coverage when wall mounted.
Installation height 10' (3m) : SETTING [8]
●
Side view
●
Side view
●
Side view
10' (3.0m)
8.5' (2.6m)
6.5' (2.0m)
66°
46°
31°
21°
13°
6°
16°
16°
16'
(4.9m)
0
33'
(10m)
66'
(20m)
82'
(25m)
55'
(16.8m)
16'
(4.9m)
0
33'
(10m)
66'
(20m)
82'
(25m)
55'
(16.8m)
16'
(4.9m)
0
33'
(10m)
66'
(20m)
82'
(25m)
55'
(16.8m)
10' (3.0m)
8.5' (2.6m)
6.5' (2.0m)
10' (3.0m)
8.5' (2.6m)
6.5' (2.0m)
4
INSTALLATION
CEILING MOUNT
WALL MOUNT OR INSTALLING ON INCLINED FACE
Loosen sensor locking screw,
turn the sensor unit
counter-clockwise and it will
come off easily.
Attach the base unit with the
arrow pointing to the direction
of ceiling.
Refer to "5 WIRING" and connect
terminals.
Twist cover counter-clockwise, while
pushing cover locking lever as the figure,
to detach cover.
Snap off limit pin near the
parabolic mirror, which release
the mirror to turn to wall
mount area.
Set area by area selector.
Put the cover on the
channel of cover spacer
(accessory).
Push cover slowly and closely
on an even surface.
Attach the cover with spacer
on the base unit,match up
marks and tighten the screw.
Attach the base unit with the
arrow pointing to the
detected area.
Refer to "5 WIRING" and
connect terminals.
Attach sensor unit to the
base unit, match up marks
and tighten the screw.
Refer to "6 AREA SETTING"
and set area by area selector.
2.60"
(66.7mm)
2.60"
(66.7mm)
3.26"
(83.5mm)
3.26"
(83.5mm)
※Match up
4 nails
PUSH
PUSH