background image

3

Top view

Vertical curtain protection

Max. coverage when ceiling mounted.
Installation height 10' (3m) : SETTING [C]

Min. coverage when ceiling mounted.
Installation height 10' (3m) : SETTING [H]

Min. coverage when wall mounted.
Installation height 10' (3m) : SETTING [8]

Side view

Side view

Side view

10' (3.0m)

8.5' (2.6m)

6.5' (2.0m)

66°

46°

31°

21°

13°

16°

16°

16'

(4.9m)

0

33'

(10m)

66'

(20m)

82'

(25m)

55'

(16.8m)

16'

(4.9m)

0

33'

(10m)

66'

(20m)

82'

(25m)

55'

(16.8m)

16'

(4.9m)

0

33'

(10m)

66'

(20m)

82'

(25m)

55'

(16.8m)

10' (3.0m)

8.5' (2.6m)

6.5' (2.0m)

10' (3.0m)

8.5' (2.6m)

6.5' (2.0m)

4

INSTALLATION

CEILING MOUNT

WALL MOUNT OR INSTALLING ON INCLINED FACE

Loosen sensor locking screw, 
turn the sensor unit 
counter-clockwise and it will 
come off easily.

Attach the base unit with the 
arrow pointing to the direction 
of ceiling.

Refer to "5 WIRING" and connect 
terminals.
Twist cover counter-clockwise, while 
pushing cover locking lever as the figure, 
to detach cover.

Snap off limit pin near the 
parabolic mirror, which release 
the mirror to turn to wall 
mount area. 
Set area by area selector.

Put the cover on the 
channel of cover spacer 
(accessory).

Push cover slowly and closely 
on an even surface.

Attach the cover with spacer 
on the base unit,match up 
marks and tighten the screw.

Attach the base unit with the 
arrow pointing to the 
detected area.

Refer to "5 WIRING" and 
connect terminals.

Attach sensor unit to the 
base unit, match up marks 
and tighten the screw.

Refer to "6 AREA SETTING" 
and set area by area selector.

2.60"

(66.7mm)

2.60"

(66.7mm)

3.26"

(83.5mm)

3.26"

(83.5mm)

※Match up 

 4 nails

PUSH

PUSH

Содержание PA-5312E

Страница 1: ...or damage to the unit if the unit falls as well as prevent the sensor from being tampered Mount the unit on a solid ceiling or wall surfaces where reinforcement materials are used If you mount the unit on non wood materials of plaster board or concrete securely mount it using anchors and mounting screws that match the wall materials Unstable mounting may result in injury and or property damage if ...

Страница 2: ...n electric shock fire and or malfunction Do not install the unit in places subject to oil smoke or steam high humidity and or a lot of dust Electricity that travels through these substances may result in fire electric shock and or false operation Ask qualified personnel for any electrical work necessary for installation if required Failure to follow this may result in fire and or electric shock Th...

Страница 3: ...ill come off easily Attach the base unit with the arrow pointing to the direction of ceiling Refer to 5 WIRING and connect terminals Twist cover counter clockwise while pushing cover locking lever as the figure to detach cover Snap off limit pin near the parabolic mirror which release the mirror to turn to wall mount area Set area by area selector Put the cover on the channel of cover spacer acces...

Страница 4: ...t 1160m 22000ft 6700m 5900ft 1800m 34000ft 10400m AWG 22 Dia 0 65mm AWG 18 Dia 1 0mm AWG 16 Dia 1 25mm 9300ft 2840m 55000ft 16500m 6 AREA SETTING PA 5312E Indicator Ceiling mount Ceiling mount Wall mount PA 5325E Ex In case of 10 3m ceiling mount height and 40 12m range selector should be set at E Ex In case of 13 4m wall mount height and 33 10m range selector should be set at 9 Ex In case of 10 3...

Страница 5: ...5 Coverage can be adjusted by turning area selector in accordance with area set chart on the back of sensor unit Loosen base unit locking screw and rotate sensor unit horizontally for adjustment ADJUST UNDER AIMING POSITION DISTANCE ft m WALL 6 5 8 5 10 13 2 0 2 6 3 0 4 0 4 6 8 11 25 7 6 33 10 0 40 12 0 45 13 7 55 16 8 60 18 3 66 20 0 75 22 8 82 25 0 3 5 6 9 3 4 5 7 2 4 5 6 2 3 4 5 2 3 4 5 1 2 3 4...

Страница 6: ...TACT CHENGEOVER SETTING OF SENSITIVITY SLIGHT MOTION DETECTION Switch 3 ON N O OFF N C Factory set Switch 6 ON Slight motion OFF Intruder detection Factory set Change alarm contact to N O when sensor is used for an application except security purpose such as light control When operation check shows you high sensitivity of sensor change setting of sensitivity with mode selector and re check operati...

Страница 7: ...it The detector reacts to passersby outside Remove the cause Change the installation location Change the installation location Shield sunrays with a blind Readjust the detection area Alarm LED lights though connected units are inactive Poor contact output connection or broken wire Check the wiring Connected units are damaged Check connected units Damaged alarm contact Check alarm output terminals ...

Страница 8: ...mm 2 31 59 3 26 83 5mm Ceiling mount Wall mount Mounting hole Ceiling mount horizontal angle adjustment Vertical angle adjustment Sensor locking screw Cover locking screw Silver White 0 18 4 5m m 25 45 30 9 0 2 0 φ7 49 φ192mm φ6 63 φ170mm 0 27 7mm 2 03 52mm 1 60 41mm 1 40 36mm Flush mount attachment BU 5300 Sensor unit Plate Flush mount box Mounting hole 8 Limited Warranty TAKEX products are warra...