33
5
Hold a cloth underneath the check valve
with strainer and remove the strainer to
drain water
Tools required: Flathead drive
* Draining and cleaning operation should be
conducted for both the hot and cold water
pipes.
Removing the strainer from the hot water may
cause output of boiling water. Utmost care must be
taken when draining hot water.
CAUTION
Maintenance Method
7
Wipe off any spilled water and remove
the cloths from the floor
6
Clean the mesh on the strainer using a
soft brush (such as toothbrush) then
return this to the original check valve
with the strainer and screw tightly
8
Check that the strainer is fitted tightly
before opening the tap
9
Press the maintenance cover onto the
front cover and close to the original state
then attach with urea screws (two
screws)
<Water leakage inspection>
Check the following every week (approximately):
• Open the maintenance cover and check for water spilled onto the floor
• Check for water spilled around the maintenance cover and side panel
If water leakage has occurred, contact your local Takara Belmont dealer because the pipe inside may be
damaged.
CAUTION
• Screw the strainer tightly.
Loose strainers may cause water leakage.
• Wipe off any drained water spilled on the floor.
Open the check valve
(Open)
Tap
Tighten
Cloth
Flathead driver
Strainer
Insert on the
top side
Front cover
Mesh
Scrub
Check valve
with strainer
Loosen