16
Adjusting the Temperature of Hot Water
(H) Hot
Stop button
1) Turn the thermostatic control knob towards H or C to
set the water to the appropriate temperature.
Turn towards H to make the water hotter and
towards C to make the water colder.
2) Continue to turn the thermostatic control knob
towards H until the knob stops at the position shown
in the figure on the right (temperature control lock
position). When water hotter than this point (about
40°C or more) is to be used, turn the knob towards H
while pressing the stop button on the thermostatic
control knob to obtain boiling water.
* The water supply temperature for the hot water supply unit should be set at least 10°C higher than
the temperature of the water output.
* The device is only capable of outputting water up to about 49°C in temperature.
(However, the value shown above applies when the water is supplied at the same pressure with
cold water supplied at 20°C and hot water supplied at 60°C in temperature, and variations may occur
in according to the hot water supply unit and pipe environment used.)
Thermostatic
control knob
Thermostatic
control knob
Maintenance cover
(H) Hot
(C) Cold
Temperature
control lock
position is here
When adjusting the temperature of the hot water,
reduce the amount of hot water and change the
direction of the shower head away the customer
and adjust the temperature while checking the
temperature with the hands. Care must be provided
during this operation because it may lead to boiling
water being output.
CAUTION
WARNING
• Check the position of the thermostatic control knob before releasing water.
Boiling water may be output and may cause burns. Also, avoid operating the
thermostatic control knob when washing the hair if a temperature higher than the
temperature control lock position is used. Error in operation may cause the hot
water to spill onto the head and cause burns.
• If the knob is turned higher than the temperature control lock position, this must
be returned to the temperature control lock position after use. Using the product
at a higher temperature may cause hot water to come in contact with the hands
and head and result in burns.
CAUTION
• Remove metal articles, such as rings and watches, before operating the thermo-
static control knob. Contact of metal articles with the thermostatic control knob
may cause the plated surface to become scratched or cracked, which may lead to
peeling of the plated surface.
• Check that there are no scratches, cracks, or peeling on the plated surface of the
thermostatic control knob.
If the plating has peeled off, discontinue use immediately and contact your local
Takara Belmont dealer. Continued use without replacing these parts may result
in injury.