10-9. Flow sensor
T-K3 Part #
#402
Takagi Part #
EKK0T
Checkpoint
H2
Function
Failure event
Effects on the T-K3
if flow sensor fails
Error codes when
the flow sensor fails.
Diagnostic
Red-Black
White(85)-Black
The flow sensor is assembled with the flow adjustment valve.
Detects and measures water flow rate using a spinning impeller and magnetic pick-u
DC 4~5.5V (Input)
441 (only within multi-unit Easy-Link systems)
Color/Number of
wires
1. Visual inspection: connection/breakage of wires and/or debris on impeller
2. Check voltages: proper range of values shown below.
DC 1~4V (pulse) 1,080 pulse/min (more than 18Hz)
Unable to detect or measure any water flow rate.
Ignition sequence does not start (T-K3 will not initiate any operation)
O U T P U T
V C C
G N D
2
2
1
1
N o . 1
3
3
W h i t e
B l a c k
R e d
N o. 3
N o . 2
Flow s ensor
>PPE-GF<
1-7/8" (47mm)
3-3/8" (84.4mm)
2 - 5 / 8 " ( 6 7 .5 m m )
Flow sensor
I N
O U T
Flow
adjustment
valve
Flow sensor
Flow
adjustment
valve
Flow sensor
O U T
I N