CONFIDENTIAL
10-18. Igniter
T-K3 Part #
#704
Takagi Part #
EKN74
Checkpoint
B2
Function
Failure event
Effects on the T-K3
if the igniter fails
Error codes when
Igniter fails.
Diagnostic
Color/Number of
wires
1. Visual inspection: connection/breakage of wires and/or an observed weak
spark.
2. Check voltages: proper range of values shown below.
Purple(7)-Purple(7) 90 VAC-110 VAC
-To ignite
the gas/air mixtures when the T-K3 is ready to burn gas on its burner
surface.
-The output voltage of the igniter is more than 14kV.
1. Unable to ignite during the ignition process.
2. Makes attempts to ignite at all times.
1. The T-K3 cannot ignite during the ignition process and the "111" or "121" error
codes will display.
2. No effects on the T-K3, however, the durability of the igniter wears down.