T-K3 Service Manual
Ver. 1.05
13
CONFIDENTIAL
10-1. Burners
T-K3 Part #
#101
Takagi Part #
EKK1N
Checkpoint
N/A
Function
Failure events
Effects on the T-K3
if burners fails
Error codes when the
burners fail
Diagnostic
Color/Number of
wires
N/A
Visual inspection: excessive dust deposit on the burner surface and/or unstable
flame conditions during operation.
There are 2 types of burners in the T-K3: the gas-rich burner stabilizes the flames
within the combustion chamber and the air-rich burner produces more heat in the
combustion chamber. The burners facilitate the air/gas mixture necessary to
produce the proper heat during the combustion reaction.
1. Unable to initialize/sustain combustion
2. Dust or soot deposit on the burner surface.
3. Cracks on the burners. 4. Gas leakage from burners
1. An unexpected combustion.
2. Unstable flame conditions and/or flame loss.
3. Ignition failure.
111
121
3 - 1 / 8 " ( 8 0 m m )
5-5/8"
(143.
2mm)
6-3/4"
(170mm)
3 / 8 " ( 1 1 .0 m m )
Si xt ee n T- K3 B ur ne rs
T- K3 B ur ne r