T-K3 Service Manual
Ver. 1.05
18
CONFIDENTIAL
10-6. AFR rod
T-K3 Part #
#716
Takagi Part #
EKK0E
Checkpoint
I
Functions
Failure event
Effects on the T-K3
if the AFR rod fails
Error codes when
the AFR rod fails.
101
991
391
Diagnostic
The AFR rod is assembled with the flame rod.
(during operation) 1
μ
A or more
-Checks flame conditions during combustion.
-When AFR rod detects unexpected flame conditions, the T-K3's computer makes
adjustments in the fan motor speed to compensate.
1. Visual inspection: connection/braking of wires, soot on it.
2. Check voltages: proper range of values are shown below.
Color/Number of
wires
1. Unable to detect flames when flames actually do occur
2. Detecting a false flame when no flames actually occur
1. The T-K3 stops operating. The "111" and/or "121" error code(s) will display
2. The T-K3 will not initiate the ignition process. The "721" error code will display
3. The fan motor speed cannot be modulated properly under abnormal flame
conditions, which can result in excessive CO emission.
Yellow (8) - Green (18)
(during operation) 40KHz~60KHz
Yellow (8) - AFR rod:
between the AFR rod and the
computer board
1 - 3 / 8 " ( 3 5 m m )
5/8"
(15mm)
7/8"
(24mm)
3-1/2
" (88.
6mm)
2-1/4"
(58.
6mm)
AFR Rod
F lame rod
Leads to computer board
Detecting elements (AFR and flame rods)