62 

18.11  Wiring diagram of PC communication 

PC

COM PORT :  

9PIN ( DTE )

SD

SG

RD

Pin 3 (T)

Pin 2 (R)

Pin 5 (G)

RS232 Connection Diagram

PC

COM PORT :  

25PIN ( DTE )

Pin 2 (T)

Pin 3 (R)

Pin 7 (G)

NOTE:

1.The length of cable be connected between controller and PC can't exceed 15 meter.

2.One Com Port can only be connected to one controller.
If more than one controller is connected to one Com Port

communication will be failed.

3.Ensure that the controller's IDNO and BAUD settings are the same with PC  software's settings.

4.For the software communication format please refer to communication manual.

SD

SG

RD

Controller

Controller

 

RS485 Connection Diagram

NOTE:

1.The length of cable be connected between Converter and Controller can't exceed 1.2 KM.
Suggestion:choose "Shielded Cable".

2.One Com Port can be connected up to a maximum of 30 Controllers.

3.Ensure that the Controller's IDNO and BAUD settings are the same with PC software's settings.

4.For the software communication format ,please refer to communication manual.

PC

Com Port

(Cable)

Converter

DCE

TxON

RxO

N

Controller

1
2
3
4

DX +

DX -

(R-)

(T-)

(T+)

(R+)

Cable

 

 

All manuals and user guides at all-guides.com

Содержание FA Series

Страница 1: ...0 All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 2: ...description 20 7 Operations 21 7 1 Power On 21 7 2 Change the Set Value SV 21 7 3 Change the Alarm Value 21 7 4 Autotuning AT 22 7 5 Programmable RAMP SOAK Only available for PFY model 23 8 Operation...

Страница 3: ...96 46 14 3 FY100 FY101 46 15 Modify input type Linear Input mA V 48 15 1 FY400 900 FU48 96 Hardware 48 15 2 FY100 101 Hardware 49 15 3 Calibration 50 16 Modify Output type Relay SSR 4 20mA 51 17 Modif...

Страница 4: ...2 2 Be sure to use the rated power supply AC85 265V or DC24V otherwise it would be caused aggravated damage on controller 3 Please confirm wires are connected with correct terminal Input Output 4 Use...

Страница 5: ...4 2 FA Series 2 1 Specifications z Standard Spec z General Spec All manuals and user guides at all guides com...

Страница 6: ...5 z Control Features z Input Features z Output Features z Communication z Alarms 2 2 Outer Dimension All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 7: ...6 2 3 Terminal Wiring Diagram All manuals and user guides at all guides com...

Страница 8: ...iring plug in out terminal M2 0 using screwdriver fix terminal M2 6 using screwdriver Selecting suitable electric wire of AWG 16 AWG22 Lock Screw torque 0 3 N m 3 kgf cm All manuals and user guides at...

Страница 9: ...ated load Voltage pulse For SSR drive ON 24V OFF 0V max load current 20mA mA dc 4 20mA 0 20mA Maximum load resistance 560 Output 1 Voltage dc 0 5V 0 10V 1 5V 2 10V Max load current 20mA Alarm 1 3A 220...

Страница 10: ...0 0 99 9A Heater Break Alarm HBA Alarm relay AL1 Available for PV or SV transmission Transmission 4 20mA 0 20mA 0 1V 0 5V 0 10V 1 5V 2 10V Remote SV 4 20mA 0 20mA 0 1V 0 5V 0 10V 1 5V 2 10V Protocol M...

Страница 11: ...l PFY400 PFY600 PFY700 PFY800 PFY900 PFY100 PFY101 Programmable RAMP SOAK 2 patterns with 8 segment each The 2 patterns can be linked together as 16 segments use All manuals and user guides at all gui...

Страница 12: ...elay SSR mA V OUT2 2 3 CLOSE OPEN COM OUT1 Proportional Motor Valve Control B Control Output mA V RTD TC mV C Input 2 3 AL 1 11 12 AL 1 13 14 AL 2 D Alarm TRS E Transmission RS232 F Communication 11 1...

Страница 13: ...otor Valve Control B Control Output mA V RTD TC mV C Input AL 1 6 7 AL 2 D Alarm TRS E Transmission RS232 G Communication 14 15 16 RD SD SG RS485 14 15 Dx Dx TTL 14 15 16 RD SD SG Option 1 2 3 4 5 6 7...

Страница 14: ...TC mV C Input 3 4 AL 2 D Alarm TRS E Transmission RS232 G Communication 15 16 17 RD SD SG RS485 15 16 Dx Dx TTL 15 16 17 RD SD SG Option COM 3 4 5 6 7 11 12 13 14 11 12 13 14 11 12 13 14 AL 1 18 19 R...

Страница 15: ...Motor Valve Control B Control Output mA V RTD TC mV C Input AL 1 6 7 AL 2 D Alarm TRS E Transmission RS232 G Communication 14 15 16 RD SD SG RS485 14 15 Dx Dx TTL 14 15 16 RD SD SG Option 1 2 3 4 5 6...

Страница 16: ...20 17 18 19 20 AL 3 39 40 Remote SV F Remote 14 15 G1 G2 OUT1 1 Zero Cross Control 40 31 33 39 PROT G1 K1 G2 K2 OUT1 1 Phase Angle Control CLOSE OPEN OUT1 COM 6 7 8 9 10 36 31 32 33 34 35 PROT RG1 RG...

Страница 17: ...16 4 6 FY100 Terminals 175mm x 110mm All manuals and user guides at all guides com...

Страница 18: ...17 4 7 FY101 Terminals 90mm x 90mm All manuals and user guides at all guides com...

Страница 19: ...18 5 External dimension and panel cutout Unit mm 5 1 FY100 5 2 FY101 All manuals and user guides at all guides com...

Страница 20: ...L PRO 1 2 50 50 44 5 0 5 44 5 0 5 65 70 FY600 96 50 90 5 0 5 44 5 0 5 111 70 FY700 FU72 74 74 68 5 0 5 68 5 0 5 89 94 FY800 FU86 96 50 44 5 0 5 90 5 0 5 65 116 FY900 FU96 96 96 90 5 0 5 90 5 0 5 111 1...

Страница 21: ...ettings are changed 6 Down key Program hold Decrease numbers 1000 100 10 1 Program hold Programmable controller 7 Up key Program run Decrease numbers 1000 100 10 1 Program run Programmable controller...

Страница 22: ...eds digit Press key to change the number to 1 Press key to store the new set value SET 7 3 Change the Alarm Value Change AL1 value to 5 0 AL1 active if PV exceeds SV over 5 0 Press key to display para...

Страница 23: ...22 7 4 Autotuning AT Use AT function to automatically calculate and set the optimize PID value for your system All manuals and user guides at all guides com...

Страница 24: ...elow use total 4 segments TIME SV RAMP SOAK RAMP SOAK 1 hour 30 minutes 50 minutes 1 hour and 20 minutes 200 120 Set SV_2 to 200 0 Set TM_2 to 00 30 30 minutes Set OUT2 to 100 0 Set SV_3 to 120 0 Set...

Страница 25: ...ter LCK in level 2 Levels entering available LCK Level 1 User Level 2 PID Level 3 Input Level 4 SET Parameters which can be changed All parameters Factory set value All parameters All parameters excep...

Страница 26: ...Process Value Set Value Output Limt Autotuning Alarm 1 set value Alarm 2 set value Set Set Set Set Set Alarm 3 set value PV SV Set Heater current display HBA set value All manuals and user guides at...

Страница 27: ...26 9 2 LEVEL 2 PID Level To enter level 2 press SET key 3 seconds in level 1 9 2 1 Level 2 parameters display hiding condition All manuals and user guides at all guides com...

Страница 28: ...if set to 0 Range 0 900 seconds PI control if set to 0 Reserved Range 0 USPL Range 0 150 seconds Relay output 10 Voltage pulse output 1 mA output 0 Range 0 1000 The same with P1 The same with I1 The s...

Страница 29: ...07 ALT means alarm on time The same with ALD1 Set Hysteresis of all Alarm Range 0 1000 Range 0 9999 Set Analog input high limit calibration Used for mA and V input Available for mA and V input Upper S...

Страница 30: ...CLO1 The same with CHO1 Retransmission high limit calibration Used for proportional motor valve control output Set Set Set Set Set Set Set Set Set Set Control mode Heat Cool Control algorithm PID Fuzz...

Страница 31: ...l 1 parameters please refer with page 17 For the description of Level 3 parameters please refer with page 20 SET Display hiding Level SET Display hiding Level 1_ 1 Level 1 5_ 1 Level 3 1_ 2 Level 1 5_...

Страница 32: ...rammable controller 0 Disable transmission 9_ 3 1 SV Transmission 0 Disable transmission 9_ 4 1 PV Transmission Used for transmission output SET 0 Remark 0 TTL Communication Slave 0_ 1 1 TTL Communica...

Страница 33: ...IFT KEY and change the setting value to 0000 9 4 3 Remote SV type selection INP2 0 None INP2 1 10 50mV 4 20mA 1 5V 2 10V INP2 2 0 50mV 0 20mA 0 5V 0 10V INP2 4 CT input Remote SV function is not avail...

Страница 34: ...Setting value of Seg 2 Set time for Seg 2 Output Limit of Seg 2 Setting value of Seg 3 Set time for Seg 3 Output Limit of Seg 3 Setting value of Seg 4 Set time for Seg 4 Output Limit of Seg 4 LEVEL 1...

Страница 35: ...ent 2 end the relay of AL1 will be on 10 seconds III END function The Controller doesn t have END order so if program procedure is less than 8 segments please set the last segments OUT to 0 Program wi...

Страница 36: ...92 0 1600 0 2912 R 0 1769 0 3216 0 1600 0 2912 S 0 1769 0 3216 B 0 1820 0 3308 0 800 0 1472 E 0 900 0 1652 0 1200 0 2192 N 0 1300 0 2372 199 9 400 0 199 9 752 0 199 9 200 0 199 9 392 0 T 0 0 350 0 0 0...

Страница 37: ...2 0 199 9 200 0 199 9 392 0 0 200 0 392 0 400 0 752 DIN PT100 0 600 0 1112 199 9 600 0 199 9 999 9 199 9 400 0 199 9 752 0 199 9 200 0 199 9 392 0 0 200 0 392 0 400 0 752 JIS PT50 0 600 0 1112 AN1 10...

Страница 38: ...Level 3 Input level If SETA_1 1 AL1 relay will be action reversely If SETA_4 0 program run alarm If SETA_4 1 program end alarm When b contact normal close is needed Only available for programmable co...

Страница 39: ...V PV Band alarm Process high alarm with hold action Process high alarm Process low alarm with hold action Process low alarm No alarm Segment End alarm Only for Programmable controller 3 ALT1 3 defines...

Страница 40: ...the AC current flowing through the heater by a Current Transformer CT and compares the CT input value and HBA set value When OUT1 is ON and CT input value is less than HBA set value during 5 seconds...

Страница 41: ...ers for HBA function Name Value Operation Level AL1 HBA Set Value Level 1 ALD1 9 Level 3 SET0 X1XX Level 4 INP2 4 Level 4 How to enter Level 3 Set parameter LCK to 0000 in Level 2 and then press SET k...

Страница 42: ...ion1 and 2 continued more than 5 seconds AL1 will be activated if condition 1 2 3 are all true 12 6 Remarks Available output OUT1 type for HBA I Relay II Voltage pulse SSR drive Since HBA function use...

Страница 43: ...L SC 80T Mechanical Dimensions mm Test Circuit 12 7 2 SC 100T Specifications Rated Primary Current Amp 0 1A 100 0A Turns Ratio 1000 1 D C Resistance Max at 20 150 Accuracy Linearity 3 Dielectric With...

Страница 44: ...15 20 25 30 35 40 45 50 55 60 65 70 75 80 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 Current Generator A FY900 Controller Current Value A Japan CTL 6 S TAIE 1 TAIE 2 TAIE 3 TAIE 4 TAIE 5 All manu...

Страница 45: ...PV exceeds USPL PV under LSPL Input signal of sub control exceeds the upper limit Remote SV Input signal of sub control under the lower limit Remote SV RAM failed Interface failed Auto tuning failed...

Страница 46: ...orwards 2 Pull out controller jumper is below the CPU 3 Turn the Power board up 4 Sensor Input TC Jumper insert the right site 5 Change Sensor input pull the Jumper out 6 Sensor Input Pt100 Jumper ins...

Страница 47: ...flat LED display forwards 2 Pull out controller jumper is below the CPU 3 Turn the Power board up 4 Sensor Input TC Jumper insert the right site 5 Change Sensor input pull the Jumper out 6 Sensor Inpu...

Страница 48: ...t type so that the new parameters could be effective 5 To change input type of TC or RTD is available but linear input is unavailable Please ask our local distributor for help 14 3 FY100 FY101 If the...

Страница 49: ...ontroller needs to modify input type from TC or mV to RTD please make PAD short on the back side of PC board as following diagram and change input selection INP1 On the contrary modify from RTD to TC...

Страница 50: ...A INP1 AN4 R3 use 100 R5 use 2 4 S3 S5 SHORT 4 20mA INP1 AN5 R3 use 100 R5 use 2 4 S3 S5 SHORT 0 1V INP1 AN4 R1 use 2K R4 use 100 S1 S4 SHORT 0 5V INP1 AN4 R2 use 10K R4 use 100 S2 S4 SHORT 1 5V INP1...

Страница 51: ...R3 use 100 R5 use 2 4 S3 S5 SHORT 0 1V INP1 AN4 R1 use 2K R4 use 100 S1 S4 SHORT 0 5V INP1 AN4 R2 use 10K R4 use 100 S2 S4 SHORT 1 5V INP1 AN5 R2 use 10K R4 use 100 S2 S4 SHORT 0 10V INP1 AN4 R3 use 2...

Страница 52: ...Adjusts ANH1 until PV Display 5000 Inputs 4mA to CHECK LOW Inputs 20mA to CHECK HIGH OK Set the range you want LOW LSPL HIGH USPL Ex Low 20 0 High 50 0 SET LSPL 20 0 USPL 50 0 DP 000 0 To display ANL1...

Страница 53: ...ORT PAD of OUT2 OPEN 12 13 14 15 16 17 18 19 20 CPU Board 96 96 48 96 96 48 11 PAD of AL3 OPEN PAD of OUT2 SHORT 8 9 10 11 12 13 14 CPU Board 6 7 8 9 10 CPU Board 48 48 72 72 PAD of OUT2 OPEN PAD AL1...

Страница 54: ...is not used please set ALD3 to 0 z SOAK I ALD1 ALD2 19 To use Sock Timer II AL1 AL2 will display as below AL1 0 0 0 0 Range 00 00 99 59 Hour Minute z Example SV 100 RAMP 10 00 min AL1 00 10 min PV 25...

Страница 55: ...G FY900 Slave 1 RD SG FY900 Slave 2 SV OUT SET0 1 1 IDNO 0 SET5 4 1 BAUD 2400 SET5 4 1 IDNO 1 SET5 4 1 BAUD 2400 SET5 4 1 open RATE function IDNO 1 SET5 4 1 BAUD 2400 SET5 4 1 open RATE function Conne...

Страница 56: ...e control z Parameter setting OUTY 4 CLO1 0 CHO1 4500 if use for resistance load CLO1 0 CHO1 4000 if use for inductor load Short CONTROLLER G 1 G 2 K 1 K 2 PROT K1 K 2 G 1 S R G 2 FAST FUSE U V SCR Mo...

Страница 57: ...control z Parameter setting OUTY 4 CLO1 0 CHO1 4500 if use for resistance load CLO1 0 CHO1 4000 if use for inductor load Short CONTROLLER G1 G2 K1 K2 PROT T1 G1 S R FAST FUSE U V TRIAC Module T2 M M V...

Страница 58: ...ase angle control z Parameter setting OUTY 5 CLO1 0 CHO1 4500 only if use for resistance load CLO1 0 CHO1 4000 if use for inductor load CONTROLLER Short K 1 G 1 K 2 G 2 K 3 G 3 T S R FAST FUSE U V DIO...

Страница 59: ...dels FY900 PFY900 FY700 PFY700 FY400 PFY400 z OUT1 1 SCR zero cross control z Parameter setting OUTY 0 CYT1 1 Short G 2 CONTROLLER G 1 G 2 PROT R S G 1 FAST FUSE U V SCR Module CYCLE TIME 200 mSEC OFF...

Страница 60: ...TRIAC z Available Models FY900 PFY900 FY700 PFY700 FY400 PFY400 z OUT1 1 SCR zero cross control z Data Change OUTY 0 CYT1 1 Short Controller G1 G2 PROT T1 G1 S R U V TRIAC T2 Load Fast Fuse All manual...

Страница 61: ...1 3 SCR zero cross control z Data Change OUTY 0 CYT1 1 RG 1 Short CONTROLLER WE CAN SUPPLY HEATER SINK RG 1 TG 1 RG 2 TG 2 PROT TG 2 TG 1 S R FAST FUSE U V SCR Module RG 2 T W CYCLE TIME 200 mSEC OFF...

Страница 62: ...z Available Models FY900 PFY900 z OUT1 3 SCR zero cross control z Data Change OUTY 0 CYT1 1 Short Controller RG 1 TG 1 RG 2 TG 2 PROT S R U V T W Fast Fuse T2 TG 1 G1 T1 TG 2 T2 G1 T1 RG 1 RG 2 All m...

Страница 63: ...101 z Data Change OUTY 3 CYT1 1 100sec Manufacturing default setting 5 seconds RUCY 5 200 seconds After change RUCY the controller must be reset 1 CYT1 is the cycle time of Open Close 2 RUCY is the 0...

Страница 64: ...same with PC software s settings 4 For the software communication format please refer to communication manual SD SG RD Controller Controller RS485 Connection Diagram NOTE 1 The length of cable be con...

Страница 65: ...63 19 Order Information 19 1 FA Series All manuals and user guides at all guides com...

Страница 66: ...64 All manuals and user guides at all guides com a l l g u i d e s c o m...

Отзывы: