Page 10
Tad Pole Hot Tub Owner’s Manual
Installation of the GFCI:
All conductors except the green
ground must be routed through the GFCI, including the
neutral. Never bypass the neutral line. If the neutral line
is bypassed, then the current will be imbalanced and
cause the GFCI to trip.
Note:
For a GFCI wiring diagram, please contact Bullfrog
International, L.C. or an authorized Bullfrog Portable Spa
Dealer.
Connecting the Spa:
1. Remove the equipment compartment door.
2. Remove the face-plate to the Control Center by
removing the four screws located in the front.
3. Connect a 1" non-metallic coupling and conduit to the
1" male CPVC pipe found at the base of the hot tub
cabinet (see “Parts Identification Diagram” in this
manual).
4. Run the required wires through the conduit and to the
Control Center.
5. Connect the 3 wires (120V systems)/4 wires (240V
systems) to the terminal block located in the Control
Center (see appropriate “Wiring Diagram”).
6. Replace the Control Center face-plate and the
equipment compartment door.
7. The electrical hook-up is complete.