Tadpole Hot Tub Owner’s Manual — January 24, 2003
120 VOLT INSTALLATION
Use only a qualified Licensed Electrician to make 120
Volt electrical installations.
Your 120 Volt spa requires a dedicated GFCI 20 AMP
electrical circuit and a minimum supply wire size of 12
gauge. It is important that this circuit is dedicated (not
being used by any other electrical appliance) or your spa
may not function properly.
Position your Tadpole Portable Hot Tub at least 5 feet
(1.5m) from all electrical outlets or devices.
240 VOLT INSTALLATION
Use only a qualified Licensed Electrician to make 240
Volt electrical installations.
Your 240 Volt Tadpole Portable Hot Tub requires a
dedicated 50 AMP electrical circuit and a minimum
supply wire size of 6 gauge. It is important that this
circuit is dedicated (not being used by any other
electrical appliance) or your hot tub may not function
properly.
Position your Tadpole Portable Hot Tub at least 5 feet
(1.5m) from all electrical outlets or devices.
30 AMP Conversion Option:
If you do not have 50
AMPS of electrical service available, your authorized
Tadpole Hot Tub Dealer or electrician can easily convert
your hot tub to operate on 30 AMPS with a minimum
supply wire size of 10 gauge. Please be aware, that hot
tub’s converted to 30 AMPS are only capable of heating
the water when the circulation pump is in low-speed, not
high-speed. This heating limitation is acceptable in most
climates as well as in indoor installations.
ELECTRICIAN'S INSTRUCTIONS:
NOTICE:
As of January 1, 1994, the National Electric
Code (Article 680-42) requires that all spas, hot tubs,
and associated electrical components shall be protected
by Ground Fault Circuit Interrupters.
Providing 120 Volt Service to the Tadpole Portable
Hot Tub:
As per code, supply a GFCI protected, 3-wire
(Line 1, Neutral & Ground), 20-AMP, 60HZ, Single-Phase
service to the front, left corner (when you are facing the
control pad) of the Tadpole Portable Hot Tub. This
service must include a disconnect that is visible from the
hot tub and located not less than five feet from the hot
tub and not more than 50 feet from the hot tub (a GFCI
Sub-Panel may be used to substitute the disconnect if
located within the same parameters).
Providing 240 Volt Service to the Tadpole Portable
Hot Tub:
As per code, supply a GFCI protected, 4-wire
(Line 1, Line 2, Neutral & Ground), 50-AMP, 60HZ,
Single-Phase service to the front, left corner (when you
are facing the control pad) of the Tadpole Portable Hot
Tub. This service must include a disconnect that is visible
from the hot tub and located not less than five feet from
the hot tub and not more than 50 feet from the hot tub
(a GFCI Sub-Panel may be used to substitute the
disconnect if located within the same parameters). Cont.