PROTOUCH-WIDE MONITOR: user documentation - PRELIMINARY
DOC/PROTOUCH-WIDE_MONITOR; V0.2
DOC_PROTOUCH-WIDE_MONITOR_V0.3.docx
Seite 14 von 35
© 2019 Syslogic Datentechnik AG | All rights reserved
Important
Note
Maximum cable length allowed for display connection is 3 m. If longer cables are used, special
overvoltage and filtering elements must be installed to comply with the requirements of EMI/RFI
CE
-certification. Only use high quality industrial devices with sufficient EMI compatibility.
2.4.6
USB Interface
The PROTOUCH-WIDE MONITOR is equipped with an USB port to connect the touchpanel to the PC
Device Connection
The USB interface uses a standard B type USB connector
Important
Note
Maximum cable length allowed for USB connection is 2.7 m. If longer cables are used, special
overvoltage and filtering elements must be installed to comply with the requirements of EMI/RFI
CE
-
certification. Only use high quality industrial USB devices with sufficient EMI compatibility.
Use shielded cables for maximum EMI protection.
Drawing excessively power might disturb operation.
2.4.7
Status LED
The two coloured LEDs shows the following states:
LED
Status
Green
Input signal OK
Red
No input signal detected
Tab. 4
Status LEDs
2.4.8
On Screen Display OSD (only on selected products)
Several display settings can be adjusted using the buttons of the OSD keyboard. The hot key function is used to access the described menu item
without having to navigate through the entire menu.
Key
Description
Hot Key Description
Menu
Open OSD menu
Menu popup / menu exit
Down
Down
Auto adjust for VGA
DEC
Enter sub-menu, decrease key or left key
INC
Enter sub-menu, increase key or right key
Source
Open Source select menu
PWR
Power on/off
Tab. 5
OSD key description