user documentation - PRELIMINARY
DOC_PROTOUCH-WIDE_MONITOR_V0.3.docx
Page 31 of 35
© 2019 Syslogic Datentechnik AG | All rights reserved
4.4
Use cases
To give an idea on how to operate the device in good condition several us cases have been defined to help system integrators choose the best
way on how to install the PROTOUCH-WIDE MONITOR
Mounting
position
CPU
load
GPU
load
Backlight
dimming
Display on-time
Airflow through
device
max. ambient
temperature
90°
30%
20%
100% (~850cd/m
2
)
all the time
1m/s
tbd
90°
30%
20%
50% (~425cd/m
2
)
all the time
1m/s
tbd
90°
30%
20%
100% (~850cd/m
2
)
all the time
2.5m/s
tbd
90°
30%
20%
50% (~425cd/m
2
)
all the time
2.5m/s
tbd
90°
30%
20%
20% (~170cd/m
2
)
5min on/10min off
none
tbd
To ensure proper operation of the device keep inside temperature below 70°C.
Operation at
70
−5
+0
°𝐶
inside temperature is only possible during 240 consecutive hours.
Important Note
Maximum ambient temperature is highly dependent on mounting, air flow and usage conditions.