PROTOUCH-WIDE MONITOR: user documentation - PRELIMINARY
DOC/PROTOUCH-WIDE_MONITOR; V0.2
DOC_PROTOUCH-WIDE_MONITOR_V0.3.docx
Seite 13 von 35
© 2019 Syslogic Datentechnik AG | All rights reserved
2.4.4
DVI
Input socket for DVI-D signals
Device Connection
The DVI-D interface uses the standard DVI-D connector
Pin Number
Signal
Pin Number
Signal
1
TMDS 2-
2
TMDS 2+
3
TMDS 2/4 SHIELD
4
TMDS 4-
5
TMDS 4+
6
DDC Clock
7
DDC Data
8
NC
9
TMDS 1-
10
TMDS 1+
11
TMDS 1/4 SHIELD
12
TMDS 3-
13
TMDS 3+
14
+5V
15
GND for 5V
16
Hot Plug Detect
17
TMDS 0-
18
TMDS 0+
19
TMDS 0/5 SHIELD
20
TMDS 5-
21
TMDS 5+
22
TMDS Clk SHIELD
23
TMDS Clk+
24
TMDS Clk-
Important
Note
Maximum cable length allowed for display connection is 3 m. If longer cables are used, special
overvoltage and filtering elements must be installed to comply with the requirements of EMI/RFI
CE
-certification. Only use high quality industrial devices with sufficient EMI compatibility.
2.4.5
DisplayPort
Input socket for displayport signals
Device Connection
The DisplayPort interface uses the standard displayport connector
Pin Number
Signal
Pin Number
Signal
1
LANE 3-
2
GND
3
LANE3+
4
LANE 2-
5
GND
6
LANE 2+
7
LANE 1-
8
GND
9
LANE 1+
10
LANE 0-
11
GND
12
LANE 0+
13
GND
14
C.E.C.
15
AUX CH+
16
GND
17
AUX CH-
18
Hot Plug Detect
19
Return for Power
20
DP Power