机床产品
/Machine Tool Products
–
610-E5/610-H5 5-Axis Wood Operation Manual
Function Key and System Configuration
–
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
ProduceCloud Setting
ServiceCloud Setting
Description of parameters
Turn On When Power On : Yes/No
Default Setting is "No". If choose "Yes", it will start up when power on.
Cloud Type : Public Cloud/Private Cloud
Only Support "ProduceCloud Setting".
Choose public cloud or private cloud according to server.
IP Address
:
Input IP address of server. The default setting is option.syntecclub.com.
Port
:
The default setting is 443.
Description of fenu button
F1
:
Save Setting
Save setting and return to "Set Kernel Server". The changes of produce cloud and service
cloud need to be saved separately.
F2
:
Cancel
Cancel and return to "Set Kernel Server".
F3
:
ProduceCloud Setting
Switch screen to "ProduceCloud Setting".
F4
:
ServiceCloud Setting
Switch screen to "ServiceCloud Setting".
OPCUA Server
Path
5 key
:
F5 Maintain
→
F2 Set Kernel Server
→
Next
→
F8 OPCUA Server
8 key
:
F5 Maintain
→
F2 Set Kernel Server
→
F8 OPCUA Server
10+8 key
:
G5 Maintain
→
F2 Set Kernel Server
→
F8 OPCUA Server
Explanation
Set the connection parameters of OPCUA server.
All setting changes take effect after reboot.
Need to enable option 51.
Require at least 20MB of memory space to start up OPCUA server.
Содержание 610-E5