The Monitor page (as well as all other pages) has a flashing green dot in the top right of the title bar
which indicates that there is a connection to the MPS and the displayed data is continuously updated. If
the connection is broken, the dot will turn red to indicate stale data.
Figure B Status "LED" on Webpage Header
3.2
CONTROL Page
The Control page is the main page to use to interact with and configure the MPS. There is a small
header section at the top which actively updates to give the present configuration and operational state.
Actions available to interact with the MPS:
Enable and disable the MPS Output
Turn on and off Battle Mode
Run fan diagnostics
Manually set fan speed
Set unit to reboot the output after a designated off time
Set the unit to shut down the output after a designated delay
Set the unit to enable the output after a designated delay
Abort a pending startup or shutdown delay
Configuration options available on the Control page are:
Set / clear auto-start option for automatic startup when power is applied
Disable automatic operation of fan diagnostics
Set auxiliary output to enable or disable with the main output
Enable or disable multi-unit on / off synchronization control
Enable or disable multi-unit fault shutdown synchronization control
Adjust input current limit parameter to avoid tripping external breakers rated below 30 A
All actions taken on the Control page take effect immediately. The Configuration options are stored to
non-volatile memory. Note that the commands will be acknowledged on the serial interface just as if
they were entered through the serial interface.