![Symmetricom TimeHub 5500 Скачать руководство пользователя страница 276](http://html.mh-extra.com/html/symmetricom/timehub-5500/timehub-5500_user-manual_1419592276.webp)
276 TimeHub 5500 User’s Guide
097-55501-01 Revision M – January 2009
Chapter 6 Specifications
Factory Default Values
Input Priority
Input no. +1
(prior to firmware
version 4263B)
PRS: 1
Others: 2
Remote: 2
(firmware version 4263B
and later)
0 to 9
Input Selection Mode
Auto
Auto | Manual | Forced
Main Clock
Y
Y (Master) | N (Remote)
Measurement Delay
0 sec
0 to 1800 sec
Output Connector Card
type
Don’t Care
Don’t Care | DS1 | CC | TS | GTS |
5MHZ
PRC Frequency
N
Y (5 MHz) | N (10 MHz)
Pull-in Range
16 (ST2)
4600 (ST3E)
10 to 10 000 ppb
Quality Cutoff
(Read Input SSM enabled)
3
1 to 9
Quality Level
(Read Input SSM
disabled)
1 (PRS)
2 (Inputs 1 –4)
1 to 9
Read Input SSM Bits
N
Y | N
Sync Mode
Auto
Auto | Manual | Force (prior to
firmware version 4263B)
Auto | SSM (firmware version
4263B and later)
Time Constant (ST2)
768
192 | 768 | 3072 | 12288 | 49152
Time Constant (ST3E)
384
102 | 190 | 384 | 1824 | 24864
Wait Time to restore Sync
source
30 sec
0 to 1000 sec
Table 6-2 Clock Card Default Settings (Continued)
Setting
Factory Default
Range
Содержание TimeHub 5500
Страница 1: ...TimeHub 5500 User s Guide Revision M January 2009 Part Number 097 55501 01 ...
Страница 12: ...List of Figures 12 TimeHub 5500 User s Guide 097 55501 01 Revision M October 2008 ...
Страница 14: ...List of Tables 14 TimeHub 5500 User s Guide 097 55501 01 Revision M January 2009 ...
Страница 46: ...46 TimeHub 5500 User s Guide 097 55501 01 Revision M January 2009 Chapter 1 Description TimeScan THC Software ...
Страница 280: ...280 TimeHub 5500 User s Guide 097 55501 01 Revision M January 2009 Chapter 6 Specifications Factory Default Values ...