180 TimeHub 5500 User’s Guide
097-55501-01 Revision M – January 2009
Chapter 4 Testing and Configuring the TimeHub
Provisioning the Outputs
Provisioning the Outputs
This section describes how to provision the outputs in a TimeHub Master/Remote or
Expansion shelf. There are several steps to provisioning the DS1, CC, and 5 MHz
outputs:
Placing in service the output card group that supplies the output
Selecting the framing for the output, if appropriate
Enabling the specific output port so that a signal will be produced on that port
Setting the output protection as desired
Setting the cable compensation for CC inputs, if applicable
For a given port to generate outputs, you must enable the port AND you must place
in-service the card group that contains that port (A, B, C, or D for the Master shelf).
To provision outputs using TL1 commands, see
You can create labels for each output port on systems equipped with IMC cards
using the new CPU that runs software version 4.1.3 or higher. See the
TimeHub
TL1 Reference Guide
for more information on port labeling.
Using TimeScan THC
You can provision outputs using the
Configuration Output
tab in the TimeScan
THC application, as shown in
.
Note:
5 MHz Output card craft software support:
System release 3.2.2: Features are designed into the 5 MHz
output card to allow TimeScan THC to support provisioning of the 5
MHz output card as if it was a DS1/CC output card. Only ports 1-4
are applicable, and the card types are reported as 55581-5MHZ for
the 5 MHz output card, and CC for the rear panel connector
module.
System release 4.1.3: TimeScan THC does not support the 5 MHz
output card in systems running release 4.1.3 or above. You can
use TL1 commands to provision the 5 MHz output card, or you can
transition to SynCraft release 1.3 or higher for full craft support of
the 5 MHz output card.
Содержание TimeHub 5500
Страница 1: ...TimeHub 5500 User s Guide Revision M January 2009 Part Number 097 55501 01 ...
Страница 12: ...List of Figures 12 TimeHub 5500 User s Guide 097 55501 01 Revision M October 2008 ...
Страница 14: ...List of Tables 14 TimeHub 5500 User s Guide 097 55501 01 Revision M January 2009 ...
Страница 46: ...46 TimeHub 5500 User s Guide 097 55501 01 Revision M January 2009 Chapter 1 Description TimeScan THC Software ...
Страница 280: ...280 TimeHub 5500 User s Guide 097 55501 01 Revision M January 2009 Chapter 6 Specifications Factory Default Values ...