Appendix 3 24VAC Wire Gauge & Transmission Distance 

The following table describes the recommended max. distance adopted for the certain wire gauge 
when the loss rate  of  24VAC voltage  is less than 10%. For the AC driven device, the maximum 
allowable voltage loss rate is 10%. For example, for a device with the rating power of 80VA which is 
installed at a distance of 35 feet (10m) away from the transformer, then 0.8000mm is required as 
the minimum wire gauge. 

 

0.8000 

1.000 

1.250 

2.000 

10 

283

86

 

451

137

 

716

218

 

1811

551

 

20 

141

42

 

225

68

 

358

109

 

905

275

 

30 

94

28

 

150

45

 

238

72

 

603

183

 

40 

70

21

 

112

34

 

179

54

 

452

137

 

50 

56

17

 

90

27

 

143

43

 

362

110

 

60 

47

14

 

75

22

 

119

36

 

301

91

 

70 

40

12

 

64

19

 

102

31

 

258

78

 

80 

35

10

 

56

17

 

89

27

 

226

68

 

90 

31

9

 

50

15

 

79

24

 

201

61

 

100 

28

8

 

45

13

 

71

21

 

181

55

 

110 

25

7

 

41

12

 

65

19

 

164

49

 

120 

23

7

 

37

11

 

59

17

 

150

45

 

130 

21

6

 

34

10

 

55

16

 

139

42

 

140 

20

6

 

32

9

 

51

15

 

129

39

 

150 

18

5

 

30

9

 

47

14

 

120

36

 

160 

17

5

 

28

8

 

44

13

 

113

34

 

170 

16

4

 

26

7

 

42

12

 

106

32

 

180 

15

4

 

25

7

 

39

11

 

100

30

 

190 

14

4

 

23

7

 

37

11

 

95

28

 

200 

14

4

 

22

6

 

35

10

 

90

27

 

 

Distance 

  (feet) 

 

Power (va) 

Wire Gauge   

(mm) 

Содержание 1080p SDI

Страница 1: ...1080P SDI PTZ Camera User Manual 1 1080P SDI PTZ Camera User Manual...

Страница 2: ...ce received including interference that may cause undesired operation EU Conformity Statement This product and if applicable the supplied accessories too are marked with CE and comply therefore with t...

Страница 3: ...ected to the power socket When the product is installed on a wall the device should be securely fixed If smoke odors or noise rise from the device turn off the power at once and unplug the power cable...

Страница 4: ...er avoid direct contact with the dome cover because the acidic sweat of the fingers may erode the surface coating of the dome cover Please use a soft and dry cloth when cleaning the inside and outside...

Страница 5: ...weight of speed dome and its accessories to ensure the effects of wind snow and rain do not weaken the mounting point Preparation of cables For the SDI speed dome the supplied cable is designed to pro...

Страница 6: ...Speed Dome 7 1 1 2 Connecting the Cables 13 1 2 DIP Switch Settings 14 1 2 1 Address Settings 15 1 2 2 Baudrate Settings 16 Appendix 17 Appendix 1 Lightning Surge Protection 17 Appendix 2 RS485 Bus C...

Страница 7: ...tallation to apply to your particular application if required Steps 1 Loosen the two lock screws as shown in the following figure 2 Remove the lower dome Figure 1 1 Disassemble the Speed Dome 3 Remove...

Страница 8: ...er and mark the holes with a permanent marker or pen then you can use this paper to mark the wall or mounting surface so you can easily drill the required holes If the supplied mounting bolts don t su...

Страница 9: ...stall the Pendant Adapter 9 Hook the two ends of the safety cable from the tab on the back of the speed dome to the loop on the underside of the wall mount respectively Route the cables through the mo...

Страница 10: ...mount to the wall or other mounting surface Be careful not to crush the wires between the mount and the wall make sure you don t leave the camera hanging from the cable while doing this Figure 1 6 In...

Страница 11: ...Align the direction label of the pendant adapter with the marking on the top of the housing to install the speed dome as shown below then push the dome up into the pendant feeding the last bit of cab...

Страница 12: ...Camera User Manual 12 15 Rotate the top casing counterclockwise or clockwise firmly to lock it in Secure the casing to the pendant adapter with the two lock screws as shown below Figure 1 8 Tighten th...

Страница 13: ...inguished by different colors Please refer to the labels attached to the cables for identification Use the supplied screw terminal blocks to connect the power connector socket to the red and black 24V...

Страница 14: ...dress and baudrate for the speed dome with value ON 1 and OFF 0 as shown in Figure 1 11 The SW1 switches from the first to the eighth are used to set the address The SW2 switches are used to set the b...

Страница 15: ...OFF ON OFF OFF OFF OFF 9 ON OFF OFF ON OFF OFF OFF OFF 10 OFF ON OFF ON OFF OFF OFF OFF 11 ON ON OFF ON OFF OFF OFF OFF 12 OFF OFF ON ON OFF OFF OFF OFF 13 ON OFF ON ON OFF OFF OFF OFF 14 OFF ON ON O...

Страница 16: ...ing the baudrate of the speed dome The baudrate can be 2400bps 4800bps 9600bps and 19200bps The baudrate will be set as 2400bps by default if it is out of this range Refer to the following table Table...

Страница 17: ...n voltage areas such as high voltage transformer substation high power lightning protection apparatus and lightning conductors should be added as necessary The design of lightning protection and groun...

Страница 18: ...situation or there are lots of devices are added to the bus on the contrary the transmission distance will be increased Connection Methods RS485 industry bus standard require daisy chain connection m...

Страница 19: ...roblem Possible Reasons To Solve the Problem The speed dome does the self test action but cannot be controlled remotely 1 The address or baudrate of the speed dome does not match with those of remote...

Страница 20: ...smoothly 1 The connection is loose 1 Reconnect the RS485 wire tightly 2 RS485 or RS485 wire is broken 2 Change RS485 wire 3 The speed dome is too far away from the remote control device 3 Add a termi...

Страница 21: ...s the minimum wire gauge 0 8000 1 000 1 250 2 000 10 283 86 451 137 716 218 1811 551 20 141 42 225 68 358 109 905 275 30 94 28 150 45 238 72 603 183 40 70 21 112 34 179 54 452 137 50 56 17 90 27 143 4...

Страница 22: ...362 1 000 18 19 0 7854 1 250 16 18 1 2266 1 500 15 17 1 7663 2 000 12 14 3 1420 2 500 4 9080 3 000 7 0683 Helpdesk Technical Support Details Swann Technical Support All Countries E mail tech swann com...

Отзывы: