Chapter 5: Local control of the equipment
User’s Manual: DT-02 Series
25
After the desired value has been set on adjustable mode of Tx power
parameter, left button should be pressed to go back to setup menu. If right
button is pressed other option will be selected; High or Low. To exit this
submenu press left button.
3.3
Input type (Analogue video, SDI or DVB-ASI
Transport Stream)
The DT-02 equipment accepts three input type signals: VIDEO (analogue
video signal, PAL), SDI (Digital video signal Serial Digital Interface) or ASI
(DVB-ASI Transport Stream, Asynchronous Serial Interface).
Once in the SETUP menu, to select the input signal type follow the steps
below:
1.
Select line no.3 (input select) using Up and Down arrows.
2.
Press right arrow to change the input signal type.
Pressing the right arrow the input signal type is changed, there is no need
to confirm the selection.
When the configured input signal type is not the same that the signal type
that is being introduced, the equipment shows an alarm and the input signal
indicator in the main screen blinks.
Figure 3.1 Main screen. Input signal type alarm (blinks
Depending on the selected input type the parameters shown in the main
screen are different.
If Video or SDI input type is selected the main screen displays the
parameters listed below: (see figure)
Audio channels status: analogue/embedded (enable/disable)
Data channel status (enable/disable)
Input signal detection (presencia/ausencia)
Coding profile (MPEG-2 4:2:0 o 4:2:2)
Delay (Standard (800ms)o Super low delay (80ms))
Blink