SV 277 PRO User Manual
48
In the
EVENT TRIGGER
tab, you can configure events for triggering markers, audio
recording and alarms.
1. Events are specified as a combination of superimposed
CONDITIONS
(logical AND)
such as specific time intervals (
Time periods
) in which measurement threshold
levels are exceed or system events occur (
Triggers
).
2. Each Event may relate to special triggers
(
ACTIONS
) such as: marker recording to
the logger file (
Marker
), audio signal recording to the wave file (
Audio
), generation of
the alarm signal on the I/O socket (
I/O alarm
), alarm SMS sending (
SMS alarm
) or
alarm e-mail sending (
E-mail alarm
).
3. Switch off the Event without deleting it. The Event becomes inactive, but you can
switch it on when needed.
When events are not defined the
EVENT TRIGGER
tab is empty.
Creating Events
To create new event, click the
field. The new
Event
area will appear in which you
can:
1. rename the event, switch it on/off or delete it, clicking on the appropriate field in the
area,
2. configure conditions, clicking on the appropriate button.