To connect a cable to a case socket, start by lining up
the key on the plug and the socket, then lock the
connector by turning the ring clockwise (only the ring
close to the socket will rotate).
To disconnect a cable, push the connector towards
the station and turn it counter-clockwise. New
connectors require more force so using a closed hand
is more effective than using only fingers.
The Lead-Acid rechargeable battery is located in the
bottom of the case.
The battery can be used in any chosen position
without the risk of leakage. The battery has a
pressure relief valves that allows safe dispersal of any
excess pressure inside the cell (VRLA).
Battery capacity may vary depending on the ambient
temperature.
The safety fuse is located on the left side of the
controller connector plate.
Note: Do not remove the battery from the case! This operation must be done
only by the authorised service.
Note: Battery is not restricted for air, surface and water transport. Classified as
non-hazardous material (IATA/ICAO Special Provision A67, DOT-CFR Title 49
parts 171-189, IMDG amendment 27).
Note: During station operation it is recommended to charge the internal battery
as often as possible; this will extend battery life. It is necessary to charge the
battery after any total discharge
.
Note: The station should not be stored for a long time with a discharged
battery. Storing with batteries in discharged condition may damage them.
Note: If the station is planned to be stored for a long period of time, it is
recommended to charge its battery to 100% capacity. The battery should be
charged at least once per 6 months.
Note: If the storage period is longer than one year, a discharge/charge cycle
must be performed. To do this, leave the device turned on until the battery is
completely discharged. Then charge the battery to 100% capacity.