INSTALLATION
Continued
INSTALLATION ITEMS
Before installing heater, make sure you have
the items listed below.
• for propane/LP gas, external regulator
(supplied by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• ground joint union
• sediment trap
• tee joint
• pipe wrench
• for natural gas, test gauge connection*
• hardware packet
- wall anchor (4)
- key (1)
- Mounting screw, black (4)
- nylon spacer (2)
- Sheet metal screw, silver (4)
* An CSA design-certifi ed equipment shutoff
valve with 1/8" NPT tap is an acceptable alter-
native to test gauge connection. The optional
CSA design-certifi ed equipment shutoff valve
can be purchased from your dealer.
LOCATING HEATER
This heater is designed to be mounted on a wall.
You can locate heater on fl oor, away from a wall.
An optional fl oor mounting stand is included.
IMPORTANT: Vent-free heaters add moisture
to the air. Although this is benefi cial, installing
heater in rooms without enough ventilation
air may cause mildew to form from too much
moisture. See Air for Combustion and Ventila-
tion, page 5. If high humidity is experienced,
a dehumidifi er may be used to help lower the
water vapor content in the air.
For convenience and effi ciency, install heater
• where there is easy access for operation,
inspection and service
• in coldest part of room
If planning to use fan, locate heater near an
electrical outlet. (Only for models
BWH20NLTB
and BWH30NLTB
)
8
WARNING: Maintain the minimum
clearances shown in Figure 4. If you
can, provide greater clearances from
fl oor, ceiling and joining wall.
WARNING: Never install the heater
in a bathroom for room heater
•
having an input rating in excess
of 6000 BTU/hr; in a bedroom or
bathroom for room heater having
an input rating in excess of 10,000
BTU/hr.
in a recreational vehicle
•
where curtains, furniture,clothing
•
or other fl ammable objects are
less than 36” (91.5 cm) from the
front, top or sides of the heater
as a fi replace insert
•
in high traffi c areas
•
in windy or drafty areas
•
CAUTION: If you install the
heater in a home garage
• heater pilot and burner must be at
least 18” (45.7 cm) above fl oor
• locate heater where moving
vehicle will not hit it
CAUTION: This heater creates
warm air currents. These currents
move heat to wall surfaces next to
heater. Installing heater next to vinyl
or cloth wall coverings or operating
heater where impurities (such as,
but not limited to, tobacco smoke,
aromatic candles, cleaning fluids,
oil or kerosene lamps, etc.) in the air
exist, may discolor walls or cause
odors.
Figure 4 - Mounting Clearances As
Viewed From Front of Heater