background image

TROUBLESHOOTING

    Continued

OBSERVED PROBLEM

ODS/pilot lights but flame
goes out when control knob
is released

P

OSSIBLE CAUSE

1. Control knob not fully
    pressed in
2. Control knob not pressed 
    in long enough
3. Safety interlock system has 
    been triggered.
4. Equipment shutoff valve 
    not fully open
5. Thermocouple connection
    loose at control valve
6. Pilot flame not touching
    thermocouple, which  
    allows thermocouple to 
    cool, causing pilot flame to 
    go out. This problem could 
    be caused by one or both 
    of the following:
   A) Low gas pressure
   B) Dirty or partially clogged
       ODS/pilot
7. Thermocouple damaged
8. Control valve damaged

1. Clean burner orifice(s) (see
    Cleaning and Maintenance,
    page 17) or replace burner
    orifice(s)
2. Contact local natural or
    propane/LP gas company

Burner(s) does not light after
ODS/pilot is lit

1. Burner Orifice(s) is clogged

2. Inlet gas pressure is too
    low

1. Contact local natural or
    propane/LP gas company
2. Clean burner orifice(s) (see
    Cleaning and Maintenance,
    page 17) or replace burner
    orifice(s)

Delayed ignition of burner(s)

1. Manifold pressure is too
    low
2. Burner Orifice(s) is clogged  

1. Clean burner orifice(s) (see
    Cleaning and Maintenance,
    page 17) or replace burner
    orifice(s)
2. Replace burner
3. Replace gas regulator

Burner backfiring during
combustion

1. Burner orifice(s) is 
    clogged or damaged
2. Burner damaged
3. Gas regulator defective

 REMEDY

1. Press in control knob fully
2. After ODS/pilot lights, keep
    control knob pressed in 30
    seconds
3. Wait one minute for safety
    system to reset.
    Repeat ignition operation
4. Fully open equipment shut-
    off valve
5. Hand tighten until snug,
    then tighten 1/4 turn more
6. A) Contact local natural or
         propane/LP gas company
    B) Clean ODS/pilot (see
         Cleaning and Maintenance,
         page 18) or replace ODS/
         pilot assembly
7. Replace pilot assembly
8. Replace control valve

22

Содержание BWH10NLM

Страница 1: ...appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach...

Страница 2: ...room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ventilation section on page 5 of this manual This appliance is on...

Страница 3: ...Keep the appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids This appliance is only for use with the 1 type of gas indicated on the rating plate T...

Страница 4: ...onal Fire Protection Association Inc Batterymarch Park Quincy MA 02269 LOCAL CODES State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massa...

Страница 5: ...osphere have a continuous water vapor retarder with a rating of one perm 6 x 10 11 kg per pa sec m or less with openings gasketed or sealed and b weather stripping has been added on openable windows a...

Страница 6: ...Hr used _______ Btu Hr maximum can support _______ Btu Hr actual amount Example 51 200 Btu Hr maximum the space can support 60 000 Btu Hr actual amount of Btu Hr used The space in the above example is...

Страница 7: ...d for use as supplemental heat Use this heater along with your primary heating system Do not install this heater as your primary heat source If you have a central heating system you may run system s c...

Страница 8: ...onvenience and efficiency install heater where there is easy access for operation inspection and service in coldest part of room If planning to use fan locate heater near an electrical outlet Only for...

Страница 9: ...re 6 Removing Shell Front Of Heater Methods For Attaching Mounting Bracket To Wall Only use last hole on each end of mounting bracket to attach bracket to wall Attach mounting bracket to wall in one o...

Страница 10: ...bracket and into wall anchors 7 Tighten screws until mounting bracket is firmly fastened to wall Placing Heater On Mounting Bracket 1 Locate two horizontal slots on back panel of heater 2 Place heate...

Страница 11: ...joint sealant lightly to male NPT threads of elbow Hold pressure regulator with a wrench when connecting elbow Do not overtighten elbow to regulator Regulator body could be damaged 3 Align holes in b...

Страница 12: ...ional CSA design certified equipment shutoff valve from your dealer 12 Figure 13 External Regulator With Vent Pointing Down Figure 14 Gas Connection INSTALLATION Continued WARNING This appliance requi...

Страница 13: ...re equip ment shutoff valve was connected 3 Pressurize supply piping system by either opening propane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for...

Страница 14: ...N CORD Use extension cord if needed The cord must have a three prong grounding plug and a three hole receptacle Make sure cord is in good shape It must be heavy enough to carry the current needed An u...

Страница 15: ...ove the white plastic screw from the cap See Figure 21 2 5 Turn it over See Figure 21 3 and reinstall it on the cap See Figure 21 4 Make sure the white plastic screw is installed on the cap tightly 6...

Страница 16: ...24 1 4 Remove the white plastic screw from the cap See Figure 24 2 5 Turn it over See Figure 24 3 and reinstall it on the cap See Figure 24 4 Make sure the white plastic screw is installed on the cap...

Страница 17: ...Make sure equipment shutoff valve is fully open 3 Turn control knob clockwise to the OFF position see Figure 25 4 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor I...

Страница 18: ...til pilot lights Keep control knob pressed in for 30 4 seconds after lighting pilot After 30 seconds release control knob Now follow step 8 under Lighting Instructions page 17 Replace Shell Front 5 OP...

Страница 19: ...orange flames with yellow tipping Dirt or other fine particles enter the heater and burn causing brief patches of orange flame Check pilot flame pattern and burner flame patterns often PILOT FLAME PAT...

Страница 20: ...e unit to cool for at least thirty minutes 2 Inspect burner pilot for dust and dirt 3 Blow air through the ports slots and holes in the burner 4 Never insert objects into the pilot tube Clean the pilo...

Страница 21: ...gnitor 1 Turn on gas supply or open equipment shutoff valve 2 Turn control knob to pilot position 3 Turn to PILOT IGN position Fully press in control knob while pressing ignitor button 4 Continue hold...

Страница 22: ...Burner Orifice s is clogged 2 Inlet gas pressure is too low 1 Contact local natural or propane LP gas company 2 Clean burner orifice s see Cleaning and Maintenance page 17 or replace burner orifice s...

Страница 23: ...8 or replace burner orifice Heater produces a whistling noise when burner is lit White powder residue forming within burner box or on adja cent walls or furniture 1 When heated vapors from furniture p...

Страница 24: ...natural or propane LP gas company 3 Clean ODS pilot See Clea ning and Maintenance page 18 Heater produces unwanted odors 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partiall...

Страница 25: ...Piezo Dimension Inches HxWxD Heater 15 4x22 5x12 1 18x26 3x12 1 25 6x26 3x12 1 Carton 17 9x23 4x11 20 1x27 2x11 28 1x27 2x11 Weight Pounds Heater 14 8 21 5 18 4 Carton 18 1 25 5 31 5 SPECIFICATIONS No...

Страница 26: ...004 1 5 Dual Fuel Regulator FCSHBF09005 1 6 Dual Fuel ODS Pilot FCSHBF09006 1 7 Base Foot FCSHBF09007 2 8 Selection Valve FCSHBF09008 1 9 Selection Valve Knob FCSHBF09009 1 10 Mounting Bracket FCSHBF0...

Страница 27: ...6 Dual Fuel ODS Pilot FCSHBF09006 1 7 Base Foot FCSHBF09007 2 8 Selection Valve FCSHBF09018 1 9 Selection Valve Knob FCSHBF09009 1 10 Mounting Bracket FCSHBF09019 1 11 Thermo Valve Assembly FCSHBF0903...

Страница 28: ...ual Fuel ODS Pilot FCSHBF09006 1 7 Base Foot FCSHBF09007 2 8 Selection Valve FCSHBF09030 1 9 Selection Valve Knob FCSHBF09009 1 10 Mounting Bracket FCSHBF09019 1 11 Thermo Valve Assembly FCSHBF09031 1...

Страница 29: ...page 7 or call Sure Heat Heating Products at 800 229 5647 for referral information When calling Sure Heat have ready model number of your heater the replacement part number SERVICE HINTS When Gas Pre...

Страница 30: ...uct to temperatures above its rated specifications which can cause considerable warping disassembly including removal of the product from a built in installation damage resulting from accident alterat...

Отзывы: